Webasto Next Operating And Installation Instructions page 21

Table of Contents

Advertisement

Description
Local load management
Table 6: Communication & functions
Description
Dimensions (W x H x D) (mm)
Weight (kg)
IP protection class, device
Protection against mechanical impact
Table 7: Mechanical data
Description
Installation location
Operating temperature range (°C)
Temperature behaviour
Storage temperature range (°C)
Permissible relative humidity (%)
Altitude (m)
Standards and guidelines
Back end integration
Tested compatible energy management sys-
tems (EMS*)
Table 8: Ambient conditions
*
Automatically available via an online update from Q2 2022.
5111232C OI-II Webasto Next_EN
Data
Dynamic (stand-alone) via incorporation of an external smart meter
Data
225 x 447 x 116
11 kW
4.6 (inc. 4.5 m cable)
5.3 (inc. 7 m cable)
22 kW
5.7 (inc. 4.5 m cable)
6.8 (inc. 7 m cable)
IP54
IK08
Data
No exposure to direct sunlight
11 kW: -30 to +55
22 kW: -30 to +45
The charging current may be reduced or the charging station may be shut down to
prevent it from overheating.
-30 to +80
5 up to 95 Non-condensing
max. 3,000 above sea level
l CE conformity
l 2014/53/EU Radio Equipment Directive
l 2011/65/EU RoHS Directive
l 2001/95/EG Product Safety Directive
l 2012/19/EU Waste Electrical and Electronic Equipment Directive
l 1907/2006 REACH regulation
Webasto ChargeConnect; connection of third-party back ends via Webasto
ChargeConnect in development
Integration into various energy management systems (EMS*) in development
Technical data | 20
*)