Setup Procedure - Renesas IECUBE2 User Manual

In-circuit emulator
Table of Contents

Advertisement

QB-V850E2
4.1.2

SETUP PROCEDURE

This section describes how to connect the QB-V850E2-SP to the IECUBE2 main.
1.Remove the cover from the connector on
the top side of the QB-V850E2-SP module.
It might be necessary to loose the screw a
little bit.
2.Make sure that the IECUBE2 is switched
off and the USB cable and power supply
adapter is not connected to the IECUBE2
main module. Then Remove the cover on
the bottom side of the IECUBE2 main
module.
3.Mount the IECUBE2 main module on the
QB-V850E2-SP as shown in the picture.
Now connect the USB cable and power
supply adapter to the IECUBE2 and turn
the IECUBE2 on.
IECUBE2 detects trace memory extension automatically when QB-V850E2-SP is connected.
Configuration in hardware or debugger software is not necessary. Please set the capacity of the trace
memory with the software tool.
R20UT0824EJ0101 Rev.1.01
2013.01.08
4.OPTIONAL PRODUCT