3. On the cable coming from the previous inverter: Con-
4. Set the DIP switch for the RS485 termination resistor to
Connecting the communication card
nect the DATA+ wire to terminal 5 and the DATA– wire to
terminal 6.
On the cable going to the next inverter: Connect the
DATA+ wire to terminal 3 and the DATA– wire to terminal
4.
the OFF position.