Connection via Wi-Fi
To use the Wi-Fi feature, the Wi-Fi module must be installed on
the inverter. The Wi-Fi module must be ordered separately from
Delta.
Connection via Sub-1G
The inverter is supplied with a Sub-1G antenna. You can order a
separate Sub-1G module for the DC1.
Required software
In order to access the DC1 and the inverter through it, you also
need:
A mobile device (smartphone, tablet) with the MyDeltaSolar
app
or
A Windows PC running the Delta Service Software (DSS)
The MyDeltaSolar app is available for iOS and Android.
You can download the DSS at https://solarsolutions.delta-emea.
com.
Installation and operation manual M70A_260 Flex RPI703M26000 EU V1.1 EN 2022-08-02
5 Planning the installation
Planning the device communication and plant monitoring

5.7.7 Connecting an external alarm unit

The inverter has two relays for triggering external alarm devices.
The communication card contains 2 pairs of dry contacts, each of
which can be connected to an external acoustic or optical alarm
device.
The communication card also has a 12 V
Both relays are designed as normally open contacts.
After commissioning, each relay can be assigned an event at
which the relay switches. By default, the relays are disabled.
To set an event for the relays, you need:
A mobile device (smartphone, tablet) with the MyDeltaSolar
app
or
A Windows PC running the Delta Service Software (DSS)
The MyDeltaSolar app is available for iOS and Android.
You can download the DSS at https://solarsolutions.delta-emea.
com.
Event
Description
Disabled
The function is disabled.
On Grid
The inverter is connected to the grid.
Fan defective The fans are defective.
Insulation
The insulation test has failed.
An error event message, fault message or
Alarm
warning has been sent.
Error
An error event message has been sent.
Fault
A fault message has been sent.
Warning
A warning message has been sent.
Table 5.6.: Events for which the relay can trigger
The default setting for both relays is Disabled.