Software Activation Key(S) - Carrier AquaForce 61XWHZE Control Manual

Smartvu control
Table of Contents

Advertisement

6 - STANDARD CONTROL OPERATIONS AND OPTIONS

6.21 - Software Activation Key(s)

61XWHZE units with SmartVu
which require Software Activation Keys:
■ BACnet communication (option 149)
■ Modbus communication (option 149B)
These software-protected options can be factory-installed or
installed on-site by the service technician.
Each option requires an individual software activation key.
To obtain the Software Activation Key, please contact your local
service representative.
6.21.1 - Software options
The list of available software activation keys can be verified via 
the Main menu.
To verify available software options
1. Go to the Main menu.
2. Select Software Options (OPT_STA). The menu can be
accessed when logged in at user access level.
• If the status of the option is set to "yes", it means that the
Software Activation Key for this option is installed.
Note:
Option 5 (Medium Brine): Not applicable to this unit
Option 6 (Low Brine): Not applicable to this unit
Option 295 (Fast Capacity Recovery): Not applicable to this unit
IMPORTANT: In case the controller is replaced, the NEW
Software Activation Key(s) based on the new MAC address
must be installed again (see also section 6.21.2).
6.21.2 - Replacement mode
If the controller is replaced with a new one, the system will be in
the Replacement mode which may last up to 7 days beginning at
the first start of the compressor.
■ When replacing the controller, it is necessary to install NEW
Software Activation Key(s).
■ Please contact your local service representative immediately
to request NEW Software Activation Key(s).
In the Replacement mode:
■ Software option(s) will be unlocked for a limited period of time
(7 days since the first start of the compressor). Only options 
that have been installed on the unit before will be active in the
Replacement mode!
■ The  list  of  available  software  options  can  be  verified  via  the 
Main menu (OPT_STA – Software Options). 
■ Alarm 10122 will be triggered. If the NEW Software Activation
Key is not installed during the Replacement mode, the alarm
will be reset automatically and software option(s) will be blocked.
42
  offer  some  additional  options 
TM
The Replacement mode ends when the Software Activation Key
is installed or the period of 7 days elapsed (7 days since the first 
start of the compressor).
IMPORTANT: Only software options that were installed on the
unit before replacing the controller will be active during the
Replacement mode!
6.21.3 - Software key installation
To install the Software Activation Key via SmartVu
1. Go to the Main menu.
2.  Navigate to the Configuration menu (logged-in users only) and 
select Add Options (ADD_OPT).
• When installing the Software Activation Key, please make
sure that the unit is stopped.
Legend
1. Controller MAC address
2. Software Activation Key
3. Enter the Software Activation Key.
• If the Software Key ends with two equality signs (==), then
these signs can be omitted. The Key will be accepted.
• The Software Activation Key is case-sensitive.
4. Once the Software Activation Key is provided in the Keyboard
screen, press OK.
5. Once the Software Activation Key is validated, the following
message will be displayed: "Software Activation Key Added".
6. The parameter connected with the activated functionality is
set automatically and the control system will also be rebooted
automatically.
• If the Software Activation Key is incorrect, the following
message will be displayed: "Software Activation Key is Invalid".
• If the Software Activation Key has been added before,
the following message will be displayed: "Key Already Set".
display
TM
B
C

Advertisement

Table of Contents
loading

Table of Contents