Starting And Stopping The Heat Pump; Starting The Heat Pump; Shutting Down The Heat Pump; Switching The Central Heating On/Off - DeDietrich HPI S Series User Manual

Reversible air/water "split inverter" heat pump
Table of Contents

Advertisement

Tab.13
Icons on the home screen and information
Icon
Information
Error status
I
OK
Maintenance status
Installer access
Holiday programme
Air source heat pump
23.5
Water pressure
,
,
,
21.7
23.5
24.5
CIRCA/CIRCB
,
,
,
19.8
23.5
23.5
,
27.5
23.5
DHW tank
Outdoor temperature
4.2

Starting and stopping the heat pump

4.2.1

Starting the heat pump

4.2.2

Shutting down the heat pump

4.3

Switching the central heating on/off

7684505 - v04 - 10022022
Description of the icon
Information on operation of the appliance
Maintenance message
Installer Level
Holiday mode in all circuits simultaneously
Heat pump flow temperature display
Current water pressure display
Symbol representing the circuit used
Circuit temperature display
Temperature display for the domestic hot water
Outdoor temperature display
1. Switch on the outdoor unit and the indoor unit.
The heat pump will begin an automatic vent cycle (which lasts
approx. three minutes), run each time the power is switched on.
2. Check the hydraulic pressure in the installation indicated on the user
interface.
Important
Recommended hydraulic pressure between 1.5 and 2.0 bar.
The heat pump must be shut down in certain situations, for example
during any intervention on the equipment. In other situations, such as an
extended absence period, we recommend that the Holiday operating
mode is used in order to benefit from the heat pump anti-blocking function
and to protect the installation from frost.
To shut down the heat pump:
1. Switch off the power to the outdoor unit.
2. Switch off the power to the indoor unit.
Your appliance will automatically deactivate the heating function and
switch to cooling mode when the temperature exceeds 22 °C (factory
setting). However, you can manually switch off the heating function for all
circuits to save energy during the summer period, for example.
4 Operation
MIT-S
15