DeDietrich HPI S Series User Manual page 9

Reversible air/water "split inverter" heat pump
Table of Contents

Advertisement

Tab.1
Outdoor unit conditions of use
Limit operating temperatures
Water in heating mode
Outdoor air in heating mode
Water in cooling mode
Outdoor air in cooling mode
Tab.2
Heating mode: outside air temperature +7 °C, water temperature at the outlet +35 °C. Performances in accordance
with EN 14511-2.
Measurement type
Unit
Heat output
kW
Coefficient of perform­
-
ance (COP)
Absorbed electrical
kWe
power
Nominal water flow
m
rate (ΔT = 5 K)
Tab.3
Heating mode: outside air temperature +2 °C, water temperature at the outlet +35 °C. Performances in accordance
with EN 14511-2.
Measurement type
Unit
Heat output
kW
Coefficient of perform­
-
ance (COP)
Absorbed electrical
kWe
power
Tab.4
Cooling mode: outside air temperature +35 °C, water temperature at the outlet +7 °C. Performances in accordance
with EN 14511-2.
Measurement type
Unit
Cooling output
kW
Energy efficiency ratio
-
(EER)
Absorbed electrical
kWe
power
Tab.5
Cooling mode: outdoor air temperature +35°C, water temperature at the outlet +18°C. Certified performances at full
load in accordance with EN 14511-2.
Measurement type
Unit
Cooling output
kW
Energy efficiency ratio
-
(EER)
Absorbed electrical
kWe
power
7684505 - v04 - 10022022
AWHP 4.5
AWHP 6
MR
MR-3
+18 °C /
+18 °C /
+55 °C
+60 °C
-15 °C /
-15 °C /
+35 °C
+35 °C
+7 °C / +25
+7 °C / +25
°C
°C
+10 °C /
+7 °C /
+46 °C
+46 °C
AWHP
AWHP 6
4.5 MR
MR-3
4.60
5.87
5.11
4.18
0.90
1.41
0.80
1.04
3
/h
AWHP
AWHP 6
4.5 MR
MR-3
3.47
3.74
3.97
3.30
0.88
1.11
AWHP
AWHP 6
4.5 MR
MR-3
4.52
4.50
2.77
2.71
1.63
1.66
AWHP
AWHP 6
4.5 MR
MR-3
6.39
7.41
2.98
2.90
2.14
2.56
AWHP 8
AWHP 11
MR-2
MR-2
AWHP 11
TR-2
+18 °C /
+18 °C /
+60 °C
+60 °C
-20 °C /
-20 °C /
+35 °C
+35 °C
+7 °C / +25
+7 °C / +25
°C
°C
+7 °C /
+7 °C /
+46 °C
+46 °C
AWHP 8
AWHP
AWHP
MR-2
11 MR-2
11 TR-2
8.26
10.56
10.56
4.27
4.18
4.18
1.93
2.53
2.53
1.47
1.88
1.88
AWHP 8
AWHP
AWHP
MR-2
11 MR-2
11 TR-2
5.93
10.19
10.19
3.12
3.20
3.20
1.90
3.19
3.19
AWHP 8
AWHP
AWHP
MR-2
11 MR-2
11 TR-2
6.65
9.90
9.90
3.00
2.77
2.77
2.22
3.57
3.57
AWHP 8
AWHP
AWHP
MR-2
11 MR-2
11 TR-2
10.29
15.49
15.49
3.15
3.48
3.48
3.27
4.45
4.45
3 Technical specifications
AWHP 16
AWHP 22
MR-2
TR–2
AWHP 16
TR-2
+18 °C /
+18 °C /
+60 °C
+60 °C
-20 °C /
-20 °C /
+35 °C
+35 °C
+7 °C / +25
+7 °C / +25
°C
°C
+7 °C /
+7 °C /
+46 °C
+46 °C
AWHP
AWHP
AWHP
16 MR-2
16 TR-2
22 TR–2
14.19
14.19
21.70
4.22
4.22
3.96
3.36
3.36
5.48
2.67
2.67
3.80
AWHP
AWHP
AWHP
16 MR-2
16 TR-2
22 TR–2
11.38
11.38
16.11
3.22
3.22
3.13
3.53
3.53
5.14
AWHP
AWHP
AWHP
16 MR-2
16 TR-2
22 TR–2
9.74
9.74
11.30
2.89
2.89
2.80
3.37
3.37
4.07
AWHP
AWHP
AWHP
16 MR-2
16 TR-2
22 TR–2
18.36
18.36
23.23
2.81
2.81
2.88
6.53
6.53
8.07
MIT-S
AWHP 27
TR–2
+18 °C /
+60 °C
-20 °C /
+35 °C
+7 °C / +25
°C
+7 °C /
+46 °C
AWHP
27 TR–2
24.40
3.80
6.42
4.20
AWHP
27 TR–2
14.70
3.13
4.70
AWHP
27 TR–2
13.20
2.82
4.69
AWHP
27 TR–2
23.52
2.85
8.25
9