6-3. Flare Compensate Adjustment

BOARD
CAM SYSCON
TP
VIDEO OUT (75 ohm termination)
ADJUST
EVR
F.NUMBER See Below
CHART
Flare Chart
M. EQ.
WFM
SPEC.
Black Level : R = G = B
1. Set the EVR as shown below.
COM:[1E] DATA:[27] ADR:[00]
2. Set the WHITE BAL SW to A position and execute
AWB, ABB, and AWB again.
<Note>
When operate AWB, connect a Waveform Monitor to
the VIDEO OUT and set Iris so that the peak level is
80%.
3. Connect a Waveform Monitor to the VIDEO OUT
and set Iris so that the peak level is 100%. Then
open the Iris 1.5 stop from the 100% position.
Ex.) F11 → → → → F8-1/2 , F11-1/2 → → → → F5.6
4. Change the R, G and B at the VIDEO OUT by
EVR and measure the each level
5. Find the lowest level of them and adjust other 2
level so that they are equal to the lowest level.
The EVR Variable Data range is 00h-64h,
The level is not changed over 64h.
R /G / B channel measurement and adjustment
[ Rch ]
(1) COM:[1E] DATA:[32] ADR:[00]
(2) COM:[0E] DATA:[00] ADR:[0B]
(3) Adjust by [← ← ← ← ]/[!].
[ Gch ]
(1) COM:[1E] DATA:[33] ADR:[00]
(2) COM:[0E] DATA:[00] ADR:[0C]
(3) Adjust by [← ← ← ← ]/[!].
[Enter]
[ Bch ]
(1) COM:[1E] DATA:[34] ADR:[00]
(2) COM:[0E] DATA:[00] ADR:[0D]
(3) Adjust by [← ← ← ← ]/[!].
ELE- 31
100%
R
G
Ex.) Rch level is lowest, so adjust G
and B levels equal to the Rch level.
[Enter]
[Enter]
[Enter]
[Enter]
[Enter]
[Enter]
B