5-5. R,G,B PED TRACK
Adjustment
BOARD
PER PROCESS
TP
CAM OUT ( 75 ohm termination)
VR104 [R TRACK]
ADJUST
VR504 [B TRACK]
EVR
F.NUMBER -
MODE
-
M. EQ.
Vector Scope
SPEC.
Center of Vector = Center of Vector Scope
Menu Setting
1. While pressing [SHIFT], [+], and [-] buttons and
set [MENU] switch to SET.
2. Set data as shown below. (Please take note if the
data is already exist. It is necessary to return
original data again after this adjustment.)
PAGE: MAIN MENU 1/4 → FLARE/GAMMA
R FLARE
G FLARE
B FLARE
R GAMMA
B GAMMA
PAGE: SERVICE ADJ 2/2.
R GAMMA (1)
B GAMMA (1)
3. Set the EVR as shown below to change the
pedestal level.
COM:[1E] DATA:[28] ADR:[00]
4. Connect a Vector Scope and set the gain to Max,
then adjust VR104[R TRACK] and VR504 [B
TRACK] precisely so that the black dot is on the
origin of the Vector Scope.
5. Set the EVR as shown below to change the
pedestal level.
COM:[1E] DATA:[29] ADR:[00]
6. Connect a Vector Scope, and confirm that the
black dot is on the origin of the Vector Scope. If it
is not adjust VR104[R TRACK] and VR504 [B
TRACK].
7. Repeat item 3 to 6.
8. After this adjustment, input original data which was
changed at step 2.
: 0
: 0
: 0
: 0
: 0
: 0
: 0
[Enter]
[Enter]
VR504
VR104

5-6. PRE AMP DC Adjustment

BOARD
PER AMP
TP104[R-SH], TP204[G-SH], TP304[B-SH]
TP
VR101[R DC], VR201[G DC], VR301[B DC]
ADJUST
F.NUMBER -
MODE
-
M. EQ.
Oscilloscope
A=0±50mVDC
SPEC.
1. Connect an oscilloscope to TP104 and adjust
VR101 so that the level A (Optical black) is in the
specification.
2. Connect an oscilloscope to TP204 and adjust
VR201 so that the level A (Optical black) is in the
specification.
3. Connect an oscilloscope to TP304 and adjust
VR301 so that the level A (Optical black) is in the
specification.

5-7. R,G,B SH Level Adjustment

BOARD
CCD PULSE, SYNC
TP102[R], TP302[G], TP502[B]
TP
(PER PROCESS)
TP3206 (SYNC) for trigger
VR102[R LEVEL] (PER AMP)
ADJUST
VR202[G LEVEL] (PER AMP)
VR302[B LEVEL] (PER AMP), EVR
Grayscale Chart
F.NUMBER
(Reflection Type 3200K)
MODE
F11 + 1/2
M. EQ.
Oscilloscope
SPEC.
A = 666 +/- 10mVp-p
1. Set the Lens Extender to X1.
2. Set the EVR as shown below.
COM:[1E] DATA:[27] ADR:[00] [Enter]
(GAIN L:0dB, KNEE:OFF, TEST PULSE:ON)
3. Connect an oscilloscope to TP3206 (SYNC
Board) for trigger.
4. Connect an oscilloscope to TP102 and adjust
VR102 so that the level A is in the specification.
5. Connect an oscilloscope to TP302 and adjust
VR202 so that the level A is in the specification.
6. Connect an oscilloscope to TP502 and adjust
VR302 so that the level A is in the specification.
ELE- 27
Level A
(Optical
Black)
A