Data output
Motorisation
Measurement
Range
Angular Measure-
ment
64
Operation
Modes
Encryption
Description
Measurement Data Output Rate
AT500 instrument
Maximum rotation speed
Acceleration lateral
Acceleration radial
Tracking speed lateral
Tracking speed radial
Angular measurement range
Horizontal
Vertical
Distance measurement range
Reflector 1.5" RRR
145°
145°
0024626 _001
Description
Resolution
Angular repeatability
Access Point Mode
Client Mode (connect to external Access Point)
WPA2 PSK
None
Value
100 points/s
Value
endless
Face 1
Face 2
Value AT500
0.8 m to 80 m (guaranteed range)
0.8 m to 160 m (typical range with
selected 1.5" reflectors)
360°
Value
0.07 arc sec
±7.5 μm + 3 μm/m
Value
180°/s
675°/s 2
180 m/s 2
145°/s
6 m/s
+75°/−55°
+85°/−55°
Technical Data