MeteoStation
Overview Camera
PowerLock
WLAN module
Technical Data
Measurement range
Temperature (internal sensor)
Temperature (external sensor)
Pressure
Humidity
Device
External Air/Object
temperature
Pressure
Humidity
* Prerequisite: External air temperature sensor is connected.
Description
Focal length
Field of view
Focus
Video Output
Update Rate
Target Recognition
Description
Field of View
Operating Range
Operating Wavelength
Standard
WLAN according to IEEE 802.11n, compatible with
IEEE 802.11b/g
Channels
Frequencies
Data Rate
Up to 150 Mbit/s
Range
–10 °C to +60 °C (14 °F to 158 °F)
–20 °C to +80 °C (14 °F to 158 °F)
500 hPa to 1100 hPa
0% to 95%
Measurement uncer-
tainty
±0.3 °C
±1.0 hPa
±10% *
Value
20.6 mm
Approximately 10° (horizontally & vertic-
ally)
At 10 m:
Horizontal ~ 1.5 m, Vertical ~ 1.5 m
~ 17 m (56 ft)
Live image: VGA (640 x 480)
Still image: 2MP; 5MP
10 fps
Supported by ATR Image Processing
Value
Approximately 10° (horizontally & vertic-
ally)
2 m to 60 m (with 1.5" RRR)
850 nm
1 to 11 (for Access Point Mode)
1 to 13 (for Client Mode)
2.412 to 2.462 (for Access Point Mode)
2.412 to 2.4835 (for Client Mode)
Applicable range
0 °C to 40 °C
(32 °F to 104 °F)
0 °C to 40 °C
(32 °F to 104 °F)
750 hPa to 1100 hPa
63