Worksheet 55: Keypad Lockout; Worksheet 111: Keypad Lockout; Worksheet 56: Communication Timers; Worksheet 112: Communication Timers - Paradox SP5500+ Programming Manual

4 to 32-zone expandable security systems
Table of Contents

Advertisement

Worksheet 54: System Timers
Section
Data
[715]
___/___/___ 000 to 255
Keypad Lockout
Use the following section to program keypad lockout settings for your SP+ control panel. Use worksheet 30 to record your settings.

Worksheet 55: Keypad Lockout

Section
[716]
___/___/___
000 to 255 minutes
[717]
___/___/___
000 to 255 attempts before locking
NOTE: For EN 50131, the keypad lockout value must be set between three and ten attempts. The minimum delay to lock must be two minutes.
Dialer Options
Table 59: Description of section [801]
Option
Description
1
Report system disarming
2
Report zone restore on closure
3 & 4
Auto-test report transmission
5
Contact ID override
6
Future use
7
Future use
8
Future use
= Default
Timers
Use worksheet 38 to record your settings for sections [820] to [840].

Worksheet 56: Communication Timers

Section
Data
[820]
___/___/___
000 to 255 hours
[830]
___/___/___
000 to 255 x 2 seconds
[831]
___/___/___
000 to 032
[832]
___/___/___
000 to 127 seconds
[833]
___/___/___
000 to 255 seconds
[838]
___/___/___
000 to 255 seconds
[839]
___/___/___
000 to 255 minutes
[840]
___/___/___
000 to 255 days
* Also applicable when using a VDMP3 Plug-in Voice Dialer.s
**The maximum value for power failure is 60 minutes.
64
Description
Recycle alarm counter
(default: 000)
Data
Description
Fail to comm. clear event timer
TLM fail delay (landline only)
Maximum dialing attempts monitoring station (landline only)
Delay between dialing attempts* (landline only)
Delay alarm transmission
Recent closing delay
Power failure report delay**
Auto test report (see
Section
Data
[723]
___/___/___ 000 to 255 seconds
* For EN 50131, the maximum value is 45 seconds.
** For EN 50131, the section must be set to a minimum of 3 and a maximum of 10
Description
Keypad lockout delay
Keypad lockout counter
OFF
Always
Bell cutoff
Disabled
Disabled
)
table 36 on page 41
SP+ Series Programming Guide
Description
Panic shutdown**
(default: 010)
Default
015 minutes
005 attempts
ON
After alarm
Zone closure
Enabled
Enabled
Default
000 = disabled
016
002
020
000
000
015
001

Hide quick links: