Zone Recognition
NOTE: For keypad zone programming, see Keypad Programming on page 7.
When expanding zones via ZX8/ZX82, up to three ZX8/ZX82 modules can be added to the system, and they are identified by the ZX8/ZX82 three-position jumpers:
+1, +9, and +17. Table 3 displays zone recognition information for SP+ control panels.
NOTE: If a device is assigned to a zone which is already programmed, a wireless zone will overwrite a keypad/hardwire zone and a keypad zone will overwrite a
hardwire zone.
Table 3: Zone recognition information for the SP+ series
SP5500+
Type
Zone
Description
1
Panel input 1
2
Panel input 2
Panel
3
Panel input 3
4
Panel input 4
5
Panel input 5
6
Input 1
7
Input 2
8
Input 3
ZX8
9
Input 4
Jumper
10
Input 5
Panel + 1
11
Input 6
12
Input 7
13
Input 8
14
Input 1
15
Input 2
16
Input 3
ZX8
17
Input 4
Jumper
18
Input 5
Panel + 9
19
Input 6
20
Input 7
21
Input 8
22
Input 1
23
Input 2
24
Input 3
ZX8
25
Input 4
Jumper
Panel +
26
Input 5
17
27
Input 6
28
Input 7
29
Input 8
30
-
-
31
-
32
-
* Please note that ATZ is only supported on the SP6000+.
12
SP6000+
Type
Zone
Description
1
Panel input 1
2
Panel input 2
3
Panel input 3
4
Panel input 4
Panel
5
Panel input 5
6
Panel input 6
7
Panel input 7
8
Panel input 8
9
Input 1
10
Input 2
11
Input 3
ZX8
12
Input 4
Jumper
13
Input 5
Panel + 1
14
Input 6
15
Input 7
16
Input 8
17
Input 1
18
Input 2
19
Input 3
ZX8
20
Input 4
Jumper
Panel + 9
21
Input 5
22
Input 6
23
Input 7
24
Input 8
25
Input 1
26
Input 2
27
Input 3
ZX8
28
Input 4
Jumper
Panel +
29
Input 5
17
30
Input 6
31
Input 7
32
Input 8
SP6000+ (with ATZ)*
Type
Zone
Description
1
Panel input 1A
2
Panel input 2A
3
Panel input 3A
4
Panel input 4A
5
Panel input 5A
6
Panel input 6A
7
Panel input 7A
8
Panel input 8A
Panel
9
Panel input 1B
10
Panel input 2B
11
Panel input 3B
12
Panel input 4B
13
Panel input 5B
14
Panel input 6B
15
Panel input 7B
16
Panel input 8B
17
Input 1
18
Input 2
ZX8/
19
Input 3
ZX82Z
X8/
20
Input 4
ZX82
21
Input 5
Jumpe
r Panel
22
Input 6
+ 1
23
Input 7
24
Input 8
25
Input 1
26
Input 2
27
Input 3
ZX8/
ZX82
28
Input 4
Jumpe
29
Input 5
r Panel
+ 9
30
Input 6
31
Input 7
32
Input 8
SP+ Series Programming Guide
SP7000+
Type
Zone
Description
1
Panel input 1
2
Panel input 2
3
Panel input 3
4
Panel input 4
5
Panel input 5
6
Panel input 6
7
Panel input 7
8
Panel input 8
Panel
9
Panel input 9
10
Panel input 10
11
Panel input 11
12
Panel input 12
13
Panel input 13
14
Panel input 14
15
Panel input 15
16
Panel input 16
17
Input 1
18
Input 2
19
Input 3
ZX8
20
Input 4
Jumper
21
Input 5
Panel +
22
Input 6
23
Input 7
24
Input 8
25
Input 1
26
Input 2
27
Input 3
ZX8
28
Input 4
Jumper
29
Input 5
Panel + 9
30
Input 6
31
Input 7
32
Input 8