Paradox SP5500+ Programming Manual page 53

4 to 32-zone expandable security systems
Table of Contents

Advertisement

SP+ Series Programming Guide
Description of Sections [966] and [967]
Table 47: Description of sections [966] and [967] (clear and reset report codes)
Option Description
1
Clear zone report codes
2
Clear user report codes
3
Clear arm/disarm/alarm report codes
4
Clear trouble report codes
5
Clear system special report codes
Clear report code for PCS lost
6
communication with panel
= Default
NOTE: When clearing or resetting any option in sections [966]
labels to their default values, before exiting the section.
Description of Sections [970], [975], and [980]
Table 48: Description of sections [970], [975], and [980]
Section Description
[970]
Downloads data from the memory key to the control panel. To download data, enter section [970], and then press
[975]
Uploads data from the control panel to the memory key. To upload data, enter section [975], and then press
[980]
Displays version number of the control panel. Once accessed, press
Label Programming with LCD Keypads
Use the information in the following section to program system labels, using an LCD keypad (K32LCD+).
Function keys
Table 49: Description of the special function keys, used for programming labels on LCD keypads
Toggle between numeric and alphanumeric keys
Toggle between lower and upper case keys
OFF
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
AND
Function
Keypad Key
Insert space
STAY
Delete
SLEEP
Delete entire entry
ARM
OFF
BYP
Insert special characters
ENTER
ON
Option Description
Enabled
1
Reset zone report codes to default
Enabled
2
Reset user report codes to default
Reset arm/disarm/alarm report codes
Enabled
3
to default
Enabled
4
Reset trouble report codes to default
Reset system special report codes to
Enabled
5
default
Reset report code for PCS lost
Enabled
6
communication with panel
[967], ensure that all other options are deselected. Press
to view the next digit.
ENTER
OFF
Disabled
Disabled
Disabled
Disabled
Disabled
Disabled
to reset the respective set of
ENTER
.
ENTER
.
ENTER
ON
Enabled
Enabled
Enabled
Enabled
Enabled
Enabled
53