Paradox SP5500+ Programming Manual page 36

4 to 32-zone expandable security systems
Table of Contents

Advertisement

Cancelling the Tamper Supervision for Wireless Sirens
To cancel tamper supervision, access section [695], and then press
Description of Sections [700] to [704]
The following section provides information on sections [700] to [704]. See table 24 for details. For keypad programming instructions, refer to
Table 24: Description of sections [700] to [704]
Option Option Type
Description
1
Partitioning
Partitioning
2
Future Use
Audible trouble warning (except AC
3
General system options
failure)
Audible trouble warning on AC failure 
4
5
RF jamming supervision
RF jamming supervision
6
Exit delay termination
General system options
Tamper supervision on the bus module 
7
8
Future Use
-
1
Panic 1
2
Panic 2
3
Panic 3
Panic options
4
Panic 1: report only or audible alarm
5
Panic 2: report only or audible alarm
6
Panic 3: report only or audible alarm
7
Future use
-
8
Future use
-
Regular arming switches to force
1
arming
Stay arming switches to stay force
2
arming
Arming/disarming options
Sleep arming switches to sleep force
3
arming
Bell squawk when arm/disarm with
4
remote
Bell squawk when arm/disarm with a
5
keypad
6
Keypad options 3
Beep on exit delay
No exit delay beeps and no bell
7
squawk, when stay/sleep arm
8
Arming/disarming options No exit delay when arm with remote
. The tamper supervision is disabled until the cover is replaced or after 30 minutes have elapsed.
ENTER
OFF
ON
Disabled
Enabled
-
-
-
-
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
-
-
-
-
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
 Report only
Audible
 Report only
Audible
 Report only
Audible
-
-
-
-
-
-
-
-
Disabled
Enabled
= Default
*All numbers from 000000 to 999999 are valid giving a total o f 1,000,000 different possible combinations.
Disabled
Enabled
**Automatic timed operation that will make indications inaccessible to users without a valid access code.
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
on page 7.
Option Option Type
Description
1
Access code length*
Access/master code
options
2
Lock master code
3
Confidential mode
Keypad options 1**
4
To exit confidential mode
5
Confidential mode timer
6
REM2 version number
REM2 version number
7
Display entry delay on LCD keypad
Keypad options 1
8
Display exit delay on LCD keypad
1
One-touch regular arming (also REM3)
2
One-touch stay arming (also REM3)
Keypad options 2
3
One-touch sleep arming (also REM3)
4
One-touch bypass programming
5
Restrict arming on battery failure
Restrict arming on tamper failure (zone
6
Arming/disarming options
+ bus module + wireless PGM)
Restrict arming on supervision trouble;
7
wireless zones & PGM + bus module
8
Future Use
-
OFF
ON
6 digits
4 digits
Disabled
Enabled
Disabled
Enabled
Enter code
Press a key
2 mins.
5 secs.
V2.01 or
V2.00
higher
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
Disabled
Enabled
-
-
-
-

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sp6000+Sp7000+

Table of Contents