Installer Quick Menu
Zones
Step Action
1
+ installer code
2
Zone number
3
Enroll or erase zone
4
Zone type
Assign partition
5
(1 and/or 2 +
)
ENTER
NOTE: If applicable, partition 2 status LEDs display signal strength of selected
wireless zone (4 LEDs = best signal; 1 LED = weak signal; no LEDs = hardwired
panel/keypad zone).
Delays
Step Action
1
+ installer code
2
1 = entry delay 1
2 = entry delay 2
3
3 = exit delay
4 = bell cut-off
4
000 to 255
Time and Date
Step Action
1
+ installer code
2
+ 5
3
Time (HH:MM)
4
Time format
5
Date (YYYY/MM/DD)
6
Details
= flash; programmed zones are lit (buttons
or LED, depending on keypad); maintenance
code may also be used
Two digits: 01 to 32
Wireless zone: open/close cover or press
/
switch; for 2WPGM remove and
LEARN
TAMPER
re-install Jumper 2 (JP2)
hardwired zone: press
;
ENTER
to erase a programmed zone, press and hold
for three seconds
SLEEP
See Zone Definitions on page 13, for the zone
type
If applicable, assign the zone to one or both
partitions, and then press
; by default, all
ENTER
zones are assigned to partition 1
Details
= flash; maintenance code may also be
used
-
Default: 045 sec.
Default: 045 sec.
Default: 060 sec.
Default: 004 min.
Entry/exit delay = seconds;
bell cut-off = minutes
Details
= flash; maintenance code may also be
used
-
If HH = 13 or more, go to step 5
1 = 24 hr. format, 2 = AM, 3 = PM
Enter the year/month/day
Walk Test Mode
Step Action
1
+ installer code
2
3
6
Installer and Maintenance Codes
Step Action
1
+ installer code
2
7 for installer
code
3
8 for
maintenance
code
4
Code
5
Confirm code
NOTE: To erase a code, press and hold
BabyWare
Step Action
1
+ installer code
2
3
9
4
Phone # +
ENTER
5
Panel ID
6
PC password
NOTE: To erase the BabyWare phone number, panel ID, and PC password,
press and hold
for three seconds.
SLEEP
Monitoring Phone Number
Step Action
1
+ installer code
2
3
1
4
Phone # +
ENTER
5
Partition 1 account #
1 for CID
6
2 for SIA
7
Partition 2 account #
NOTE: To erase monitoring phone number, reporting format, and account
numbers, press and hold
for three seconds.
SLEEP
Details
= flash; maintenance code may also be
used
-
Activates or deactivates walk test mode
Details
= flash
-
-
Enter a four or six-digit code
Re-enter the four or six-digit code, to confirm
for three seconds.
SLEEP
Details
= flash
-
-
Enter PC phone number (up to 32 digits), and
then press
ENTER
Enter four-digit panel ID
Enter four-digit PC password
Details
= flash
-
-
Enter monitoring station phone number (up
to 32 digits), and then press
ENTER
-
SIA is not supported with GPRS/IP reporting
-

Hide quick links: