Paradox SP5500+ Programming Manual page 37

4 to 32-zone expandable security systems
Table of Contents

Advertisement

SP+ Series Programming Guide
Zone Options
Use the following section to program zone options for your SP+ Series control panel.
ATZ, Zone Tamper, and Supervision Options
Table 25: Description of section [705]
Option Description
1
ATZ zone doubling
2
ATZ wiring options
3
Tamper recognition
4
5
Generate tamper on bypassed zone
6
Supervision options
7
8
Generate supervision on bypassed zone
= Default
NOTE: ATZ is only available for the SP6000+.
Table 26: Description of options 3 & 4 and 6 & 7, in section [705]
Option
3
4
RF Zone/Hardwired Zone Tamper Recognition Options
OFF
OFF
Disabled
OFF
ON
Trouble only
ON
OFF
When disarmed: trouble only; when armed: follow zone's alarm type
ON
ON
When disarmed: audible alarm; when armed: follow zone's alarm type
6
7
RF Zone Supervision Options
OFF
OFF
Disabled
OFF
ON
Trouble only
ON
OFF
When disarmed: trouble only; when armed: follow zone's alarm type
ON
ON
When disarmed: audible alarm; when armed: follow zone's alarm type
* Tamper recognition of keypad/bus module, only if section [700], option 7, is enabled.
General Zone Options
Table 27: Description of section [706]
Option
1
Check-in supervision time
2
EOL resistors (applies to all hardwired zones – panel, keypad, ZX8/ZX82)
3
Zone input 1 becomes a two-wire smoke input
4
ZX8/ZX82 ID A (panel + 1) input 1
5
ZX8/ZX82 ID B (panel + 9) input 1
6
ZX8/ZX82 ID C (panel + 17) input 1
= Default
OFF
ON
Disabled
Enabled
Series
Parallel
(see table 26 for details)
No
(see table 26 for details)
No
Description
Yes
Yes
Description
Keypad/Bus Module Tamper Recognition Options*
Disabled
Trouble only
Trouble only
Audible alarm
Keypad/Bus Module Supervision Options
Disabled
Trouble only
Trouble only
Audible alarm
OFF
24 hours
Disabled
Disabled
Zone input
Tamper input
Zone input
Tamper input
Zone input
Tamper input
ON
80 minutes
Enabled
Enabled
37