SP+ Series Programming Guide
SP7000+ PCB Layout
1 Four-pin connector can be used for quick installation of a keypad
2 AUX LED:
ON = Aux present; OFF = Aux off
3 Panel reset
4 EBUS and Dialer used with:
VDMP3 Plug-In Voice Module for voice reporting
PCS Series Communicator Module
LEDs
5
Status LED:
Flash once every second: Normal
Flashes ON 1 sec. and OFF 1 sec.: Any trouble
Always ON: Panel is using phone line
Fast flash 6 seconds after power-up: Installer lock enabled
Charge LED:
Charging and battery test LED
6 Serial 1: Used as the primary reporting channel for connecting the IP
Module/PCS Module
7 Serial 2: Used as a backup reporting channel for connecting the IP
Module/PCS Module
The sum of the current drawn from the
and lead to complete system shutdown.
40 VA transformer strongly required.
This equipment must be installed and maintained by qualified service personnel only.
Max. number of keypads: 15 bus modules
Max. aux. current: 1500mA
Power consumption (idle): 46mA
Max. distance of bus module from panel: 76 m (250 ft.)
Max. total run of wire: 230 m (750 ft.)
and
must be limited to 2.1A. Exceeding this limit will overload the panel power supply
BELL
AUX
Enter section [300] to
unlock your SP+ panel
serial ports for use with
third-party devices
using a TM70/TM50
Touch keypad, and
K32LCD+.
To provide maximum lightning
protection we strongly
recommend having separate
earth connections for the dialer
and zone ground terminals.
8 Zone Input
9 The
output will shutdown if the current exceeds 3A
BELL
10 PGMs: these jumpers allow you to choose whether the solid state relay
PGMs are grounded (-), or give out 12V (+)
11 AC Power connections
12 Backup Battery connections
13 AWG#14 single conductor solid copper wire
14 Ground clamp
15 Cold water pipe grounding
16 To ground
17 Keypad's zone configuration
18 Zone connections, if EOL is enabled, see section [706] option 2
19 To connect additional wiring to auxiliary power, use the red (+) and black
(-) keypad connectors; auxiliary power will shut down if current exceeds
1.1A; if the auxiliary output is overloaded and shuts down, you must
disconnect all loads from the output for at least 10 sec. before
reconnecting any load back to the auxiliary output
Do not cut, bend, or alter
the antenna, and ensure
that electrical wires or
other type of wires do
not cross over it, as this
may affect signal
reception. Do not install
the antenna near wires as
it may cause
interference.