Wireless Zone Assignment
Use the following section to program the wireless zones on your SP+ Series control panels. Use worksheet 10 to record your settings.
Worksheet 10: Wireless Zones
Section
Zone
Wireless Zone (Serial #)
[061]
1
___/___/___/___/___/___
[062]
2
___/___/___/___/___/___
[063]
3
___/___/___/___/___/___
[064]
4
___/___/___/___/___/___
[065]
5
___/___/___/___/___/___
[066]
6
___/___/___/___/___/___
[067]
7
___/___/___/___/___/___
[068]
8
___/___/___/___/___/___
[069]
9
___/___/___/___/___/___
[070]
10
___/___/___/___/___/___
[071]
11
___/___/___/___/___/___
NOTE: When assigning wireless zones, enter the serial number, or press
number, enter 000000.
Wireless Transmitter Signal Strength
The signal strength test for wireless transmitters is performed in sections [101] to [132]; these sections represent zones 1 to 32, respectively. To test the wireless
transmitter strength of your various wireless devices, proceed as follows:
1.
Enter the zone's respective section (e.g., for zone 1, enter section [101]).
2.
For all wireless transmitters except 2WPGM: Press the transmitter's anti-tamper switch and note the number of beeps which are emitted. As shown in table 9,
the number of beeps correspond to a preset signal strength range.
For the 2WPGM: Remove and re-install Jumper 2 (JP2).
Table 9: Signal strength indicator for wireless transmitters
Number of Beeps
Signal Strength
3
8 to 10
2
5 to 7
1
1 to 4
NOTE: The visual representation of a transmitter's signal strength is dependent on the type of keypad. For LED keypads, zones 1 through 10 will illuminate,
depending on the signal strength. For instance, a signal strength of 8 will result in zones 1 through 8 to illuminate. For LCD keypads, a ten-level progress bar
composed of arrows will appear, followed by the numeric value. For a signal strength of 8, eight arrows will appear, followed by the number 8.
Zone Report Codes and Labels
Use the following section to program zone report codes and labels on your SP+ Series control panels.
Zone Report Codes
Use worksheet 11 to record your settings when programming zone report codes.
Worksheet 11: Zone Report Codes
Alarm
Section
Zone
Report
Codes
Report Codes
1
___/___
[141]
2
___/___
[142]
3
___/___
[143]
4
___/___
[144]
5
___/___
[145]
6
___/___
[146]
7
___/___
[147]
8
___/___
[148]
9
___/___
[149]
10
___/___
[150]
11
___/___
[151]
12
___/___
[152]
13
___/___
[153]
14
___/___
[154]
15
___/___
[155]
16
___/___
[156]
16
Section
Zone
[072]
[073]
[074]
[075]
[076]
[077]
[078]
[079]
[080]
[081]
[082]
Result
Strong signal
Average signal
Weak signal (relocate)
Alarm
Tamper
Tamper
Restore
Report
Restore
Codes
Report Codes
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
Wireless Zone (Serial #)
12
___/___/___/___/___/___
13
___/___/___/___/___/___
14
___/___/___/___/___/___
15
___/___/___/___/___/___
16
___/___/___/___/___/___
17
___/___/___/___/___/___
18
___/___/___/___/___/___
19
___/___/___/___/___/___
20
___/___/___/___/___/___
21
___/___/___/___/___/___
22
___/___/___/___/___/___
/
; for the 2WPGM, remove and re-install Jumper 2 (JP2). To delete the serial
TAMPER
LEARN
Alarm
Section
Zone
Report
Codes
17
___/___
[157]
18
___/___
[158]
19
___/___
[159]
20
___/___
[160]
21
___/___
[161]
22
___/___
[162]
23
___/___
[163]
24
___/___
[164]
25
___/___
[165]
26
___/___
[166]
27
___/___
[167]
28
___/___
[168]
29
___/___
[169]
30
___/___
[170]
31
___/___
[171]
32
___/___
[172]
SP+ Series Programming Guide
Section
Zone
Wireless Zone (Serial #)
[083]
23
___/___/___/___/___/___
[084]
24
___/___/___/___/___/___
[085]
25
___/___/___/___/___/___
[086]
26
___/___/___/___/___/___
[087]
27
___/___/___/___/___/___
[088]
28
___/___/___/___/___/___
[089]
29
___/___/___/___/___/___
[090]
30
___/___/___/___/___/___
[091]
31
___/___/___/___/___/___
[092]
32
___/___/___/___/___/___
Alarm
Tamper
Tamper
Restore
Report
Restore
Report Codes
Codes
Report Codes
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
___/___
Need help?
Do you have a question about the SP5500+ and is the answer not in the manual?