Magellan & Spectra SP • Programming Guide
Miscellaneous System Options
Table 29: Description of section [708]
Option
1
Enter code to view trouble
2
Enter code to view alarm in memory/event list
3
Trouble latch
4
Bell squawk on Installer in
5
Acknowledge trouble(s) before arming
6
Do not arm if zone opens during exit delay
7
Disable 'Bypass and Arm'
8
Future use
= Default
System Timers
Use the following section to program system timers on your MG/SP control panel. Use worksheet 29 to record your settings.
Worksheet 29: System Timers
Section
Data
[710]
___/___/___ 000 to 255 seconds Entry delay 1* (default: 045)
[711]
___/___/___ 000 to 255 seconds Entry delay 2* (default: 045)
[712]
___/___/___ 000 to 015
[713]
___/___/___ 000 to 255 seconds Intellizone delay (default: 048)
[714]
___/___/___ 000 to 255 minutes Recycle alarm delay (default: 000)
[715]
___/___/___ 000 to 255
Keypad Lockout
Use the following section to program keypad lockout settings for your MG/SP control panel. Use worksheet 30 to record your settings.
Worksheet 30: Keypad Lockout
Section
[716]
___/___/___
000 to 255 minutes
[717]
___/___/___
000 to 255 attempts before locking
NOTE: For EN 50131, the keypad lockout value must be set between three and ten attempts. The minimum delay to lock must be two minutes.
Programming the Daylight Savings Feature
Use the following section to program Daylight Savings Time on your MG/SP control panel. Use worksheet 31 to record your settings.
Table 30: Description of section [730]
Section Option
Description
Daylight savings (not applicable to
[730]
1
SP4000 and SP65)
= Default
Version 4.7/4.92/5.12
Description
Description
Auto-zone shutdown counter
(default: 005)
Recycle alarm counter
(default: 000)
Data
OFF
Disabled
OFF
One-touch
One-touch
Disabled
Disabled
Disabled
Disabled
Disabled
Section
Data
[718]
___/___/___ 000 to 255 seconds
[719]
___/___/___ 000 to 255 days
[720]
___/___/___ 000 to 255 seconds Flex-instant delay (default: 015)
[721]
___/___/___ 000 to 255 seconds
[722]
___/___/___ 000 to 255 times
[723]
___/___/___ 000 to 255 seconds
* For EN 50131, the maximum value is 45 seconds.
** For EN 50131, the section must be set to a minimum of 3 and a maximum of 10
Description
Keypad lockout delay
Keypad lockout counter
ON
Enabled
ON
Enter code
Enter code
Enabled
Enabled
Enabled
Enabled
Enabled
Description
Remote panic disarm lock delay
(default: 000)
Closing delinquency delay
(default: 000)
For StayD: re-arm delay
(default: 005)
Auto trouble shutdown**
(default:000)
Panic shutdown**
(default:000)
Default
000
000
System Timers | 39