I/O Connector; Safety Precautions - Advantech MVP-3245 Series User Manual

4-axis embedded motion controller
Table of Contents

Advertisement

Protection
1.2.2.5
Digital Output
Item
Channel
Output Voltage
Maximum Sink Current
Protection
1.2.3

I/O Connector

1.2.3.1
Digital Input
Item
Channel
Input Voltage
Maximum Delay
Time
Protection
1.2.3.2
Digital Output
Item
Channel
Output Voltage
Maximum Sink Current
Protection
1.3

Safety Precautions

The following safety precautions can help customers with establishing a connection.
Generally, a standard cable is enough for the connection.
Note!
Always disconnect the power cord from the chassis when making
adjustments. Do not connect when the power is on. A power spike can
damage sensitive electronic components. Only experienced electronics
personnel should open the chassis.
Note!
Always ground yourself to remove any static electricity before touching
the MVP-3245. Modern electronic devices are very sensitive to static
electricity. Use a grounding wrist strap at all times. Place all electronic
components on a static-dissipative surface or in a static-shielded bag.
MVP-3245 User Manual
2,500 V isolation
Description
SVON, ERC, CMP, CAM-DO
Low
10 V
DC
High
30 V
DC
100 mA / channel
2,500 V isolation
Description
16
Low
Max 2 V
DC
High
Min 5 V
DC
Max 30 V
DC
100 μs
2,500 V isolation
Description
16
10 ~ 30 V
300 mA / channel
2,500 V isolation
4