11 .lO Remote Called Station Message Mode
Any electronic telephone button can be
activated from the remote terminal at any
time while in the Test Mode (even while the
end user is using the electronic telephone).
Therefore, caution must be used toprevent
service interruption
or interference. The
Test Mode provides status tests to check
whetherornotastationorCOlineisinuse.
The status checks should always be made
before performing other tests.
11 .I 1
Allows the terminal
to set a Called Station
Message
for an originating
station with the destina-
tion of the message
being a station
or group
of
stations.
11 .I
2 When the message
is set, the MW/FLLED(s)
on the destination
station(s)
flash.
10.10 CO Line Testing
11 .I
3 When a destination
station calls the originat-
ing station,
the message
is displayed
on the desti-
nation station's
LCD.
10.11
To test CO line transmission,
two or three
CO lines must be available
at the remote
site (see
Figure 5).
10.12
CO line testing is accomplished
by using all
of the following
three methods:
Mode 94:
To edit and/or
review a Called Station
Message
before setting
it, use this mode.
It will
print out the existing
message
and allow addi-
tions to it (such as a time or a date) before it is set.
(The
message
cannot
be changed
with this
mode-just
added
to.)
1)
2)
3)
Call station B at the remote site via the STRATA
system and then place the line on hold (trans-
mission
is checked
at the remote
site via
MOH).
Establish
a talk path between
the two remote
stations
(B & C) via a CO-to-CO
connection
through
STRATA.
Establish
a talk path between
a remote station
and the time or weather
service via a CO-to-
CO connection
through
STRATA.
10.13
The procedures
in the tables
provide
ex-
amples of the types of tests and functions
that can
be accomplished
with the Test Mode. These proce-
dures do not cover all the possible tests that can be
performed
remotely;
however,
by using the prin-
ciples given, other tests are possible.
11 MESSAGE
MODE
11 .OO General
11 .Ol
This mode allows a local or remote terminal
to set Called and Calling Station LCD messages
for
station
users. The messages
may be system
or
station
type
and are stored
in their
respective
memory
locations
when set.
Mode
96: To add or change a Called Station
Mes-
sage before setting it, use this mode. It does not
display the existing
message,
but allows a com-
pletely new message
to be entered
before
it is
set.
11.20 Remote Calling Station Message Mode
11.21
Allows the terminal
to set a Calling Station
Message
for a station.
The message
will be set on
the station's
LCD and is automatically
displayed
on
other stations'
LCDs whenever
they call that sta-
tion.
Mode
95: To edit and/or
review a Calling Station
Message
before
setting
it, use this mode.
It will
display the existing message
and allow additions
to it (such as a time or adate)
before it is set. (The
message
cannot
be changed
with this mode-
just added
to.)
Mode 97:
To add or change
a Calling
Station
Message
before setting it, use this mode. It does
not display the existing
message,
but allows a
completely
new message
to be entered
before it
is set.
11.22
Use the procedures
in the tables
to set
messages
via Modes
94/96 and 95/97.
-9-

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk56Strata dk96

Table of Contents