INSTALLATION-PERIPHERALS
SECTION 200-096-208
FEBRUARY1991
l
SWI-4:
This switch is placed in the ON position
if the computer
does not output
the RTS signal.
Sometimes,
the DTE device may use RTSKTS
for Ready/Busy
flow
control,
in these
cases
SWl-4
should
be OFF. In this case the DCD
signal of the calling DTE is used as the RTS lead
of the called
DTE and the DCD signal of the
called DTE is used as the RTS signal of the other
DTE. In this case a signal which stops the DTE
from transmitting
data (usually
the CTS lead)
should
be cross-connected
to the DIU's DCD
signal.
Consult
the DTE device
or application
software
documentation
to determine
which type
of flow control
is required.
12.40 PDIU-DI to Personal Computer (PC) In-
stallation
12.41
The PDIU-DI
always
functions
as a DCE
device; it transmits
data on the Receive
Data lead
(RD) and receives
data on the Transmit
Data lead
(TD). Most personal
computers
function
as a DTE
device;
PCs transmit
data
on the TD lead and
receive data on the RD lead. Follow the steps below
to install the PDIU-DI
to a DTE, PC:
NOTES:
1. Use the steps below
when
installing
an
ASCII terminal, personal
computer,
or any
other DTE device to a PDIU-DI.
2. The
PDIU-DI
can
connect
to a DCE
computer
or any other DCE-type
device
using a specially configured
W-232
cable
or adapter;
but this application
is rarely
required.
1) Install
the digital
telephone
that
is to be
equipped
with PDIU-DI
per the instructions
in
Section 200-096-207
and the drawing
in Sec-
tion 200-096-209.
2) Install the PDIU-DI
under the digital telephone
per the instructions
in Section 200-096-207.
NOTE:
The PDIU-DI
always operates
as a DCE de-
vice; therefore,
unlike the PDIU-DS,
it has no
internal jumpers.
3) Connect
the appropriate
RS-232
cable
be-
tween the PDIU-Dl's
DB-25female
connector
and the PC's appropriate
asynchronous
serial
communications
port connector
(C'OM port).
IMPORTANT NOTE!
Check the PC manufacturer's serial com-
munica tion port interface documentation
for correct RS-232 pin requirements;
re-
quirements vary with each manufacturer.
The number of ElA RS232signals required
(8, 9, or IO wires) depends on the applica-
tion. When EIA signal requirements are not
known, connect the 10 EIA signals listedin
Paragraph 12.20. Figures 8-29 and 8-30
provide diagrams for connecting RS-232
cables between PDIU-Dls and Toshiba lap
top, and IBM, XT and AT PCs.
4) SetthePDIU-DI
DIPswitch
(SWl-I-4)forthe
desired
application.
Figure
8-26 shows
the
DIP switch
locations
and Paragraph
12.30
describes
switch functions.
5)
Access
Program
20 to configure
the PDIU-DI
for DTE-type
connection
and
Program 39
for
data button
assignments
of the digital tele-
phone connected
to the PDIU-DI.
Program 20
l
The port number
entered for the PDIU-DI
in
Program
20 is the port number
of the
digital telephone
to which the PDIU-DI
is
connected.
l
LED 01:
Should always be ON for PDIU-
DI ports.
l
LED
02: Should be ON for PDIU-DI ports,
unless the PC user will never use DIU AT
commands
(other
than
ATDD,
ATDT,
and ATD) and never require the PDIU-DI
to send result codes to display on the PC
display screen. Frequently,
it is difficult to
determine
the full extent
of these
re-
quirements;
so it is recommended
to turn
LED 02 ON. See the Data Interface
User
Guidein the Operating
Procedures
of the
Installation
and Maintenance
Manualfor
information
regarding
D!U ATcommands
and result codes.
l
LEDs
03
and
04: Should
be OFF for
PDIU-DI
ports.
8-41