Circuit Breaker Distribution; Voltage Troubleshooting; Ppsu96 Front Panel And Dc Out Test Points; Lower Left Of Dk24, Backplane Pcb (Pmb-824) - Toshiba STRATA DK24 Manual

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

INSTALLATION-KSU
SECTION 200-096-205
FEBRUARY 1991
DC OUT
+SJ,
0
0'
-5V,
-24Vj
-24V2
0
0
-24V3
0
PPSU96
("
FIGURE 5-4-PPSU96 FRONT PANEL AND DC
OUT TEST POINTS
2) Reach behind
the power supply,
and connect
the cable from the rear of the power supply into
connector
Pl on the KSU backplane.
3) Slide the power supply completely
into the slot
and secure it with screws (2) on the right side of
the KSU.
4.22
DK56196.
Refer to Figures
5-3 or 5-4, and
replace
the power supply
in accordance
with the
following
steps:
1) Slide the new power supply into the opening
in
the KSU.
2) Align the mounting
screw holes on the power
supply's front panel with the holes in the KSU's
power supply mounting
bracket.
3) Secure the power supply with the four combina-
tion slotted/Phillips
screws.
4) Insert the DC OUT cable plug into the DC OUT
connector
(this is a keyed plug that can only be
FIGURE 5-5-LOWER LEFT OF DK24,
BACKPLANE PCB (PMB-824)
inserted
one way).
Insert
the plug into the
connector
until its locking tab engages.
5 CIRCUIT BREAKER
DISTRIBUTION
5.00
Referto
Fault Finding, Section 200-096-500,
Tables
B, C, and D for circuit breaker
distribution.
6 VOLTAGE TROUBLESHOOTING
6.00
Refer to Fault Finding, Section 200-096-500,
Paragraph
6, for voltage
troubleshooting.