INSTALLATION-PERIPHERALS
SECTION 200-096-208
FEBRUARY1991
l
LED
05: Should
be ON if the system
is
installed
behind
a PBX or Centrex
that
uses access
codes
to make
external
calls or to insert a pause
following
DIU
access of an outside
line.
l
LEDs 17
m 20: Used to establish
data
security
groups.
PDIU stations
are only
allowed
to make calls to PDlUs
in the
same data group to which they are as-
signed.
Program 39
l
The following
data call buttons
can be
assigned digital telephones
equipped
with
and mm.
buttons
to data
devices
as required.
Do not assign m
buttons to data devices; m
buttons are
used for voice calls only.
12.50 PDIU-DS To Printer Installation
12.51
The STRATA
DK
(Release
3) enables serial
printers
(laser,
dot matrix,
or other types)
to be
connectedtostand-alonedatainterfaceunits(PDIU-
DSs). Digital telephones
equipped
with PDIU-Dls
can share access to these printers.
Serial printers
operate
as DCE or DTE devices, depending
on the
vendor;
the PDIU-DS
can be connected
to either
type, since it can be configured
as a DTE or DCE
device.
(The
PDIU-DS
comes
from
the factory
configured
as a DCE device.)
Follow
the steps
below to install the PDIU-DS
to a serial printer.
NOTES:
1. Only serial printers
(not parallel)
that con-
form to EIA RS-232signaling
requirements
can be connected
to PDIU-DSs.
2. In rare applications,
it may be desired
to
connectprinters
to PDIU-Dls.
Refer to the
printer's
ins talla tion instructions.
1) Consult theserial
printer's documentation
and
determine
if the printer operates
as a DCE or
DTE device:
l
If the printer
is a DCE device:
Disas-
semble
the PDIU-DS
and configure
it to
operate
like a DTE device by placing the
jumper plugs
(PI - P9)
in the "B-C" (MO-
DEM) position.
Reassemble
the PDIU-
DS, and mark "B-C" on the bottom
iden-
tification label for future reference.
(Para-
graph
12.70
provides
PDIU-DS
disas-
sembly/assembly
instructions,
and Figure
8-28 provides jumper
plug information.)
l
If the printer is a DTE device:
It may not
be necessary
to disassemble
the PDIU-
DS, since it comes direct from the factory
configured
as a DCE device. However,
if
uncertain,
disassemble
the PDIU-DS and
verify that jumper
plugs
(Pl - P9)
are in
the "A-B" (DTE) position.
Reassemble
the
PDIU-DS
and
mark
"A-B" on the
bottom
identification
label for future
ref-
erence. (Paragraph
12.70
provides PDIU-
DS disassembly/assembly
instructions,
and Figure
8-28 provides
jumper
plug
information.)
2) Connect the PDIU-DS to the appropriate
PDKU
circuit perwiring
diagrams
in Section 200-096-
209 and information
provided
in Section 200-
096-207.
3) Connect
the appropriate
RS-232
cable
be-
tween the printer and the PDIU-DS
(see Fig-
ure 8-31 for an example
printer cable connec-
tion).
4) If steps 2 and 3 are done properly,
the Power
and Ready LEDs on the PDIU-DS
should light
when the printer is turned
on and ready.
5) Set the PDIU-DS
DIP switch
(SWI-1 - 4)
for
the desired application.
Figure 8-26 shows the
DIP switch
locations
and Paragraph
12.30
describes
switch functions.
IMPORTANT NOTE!
Check the printer's serial documentation
for correct RS-232 pin requirements.
The
requirements vary with each manufacturer.
6)
Use
Program
20 to configure
the PDIU-DS
to
connect
to a serial printer
(see Pogramming
Section
200-096-302
for instructions
and
record sheets).
l
LED 01:
Should al'ways be-ON for PDIU-
DS ports.
8-42

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk56Strata dk96

Table of Contents