outward.
If the connectors
are properly mated,
a slight resistance
will be felt.
NOTES:
1. Do not adjust trimmer
capacitor
C4. The
capacitor
is factory-calibrated.
2. When transporting
the PCTU, keep the P7
battery
strap in the ON position
if it is de-
sired to save the configuration
data stored
in PCTU
RAM
(the battery
will protect
RAM for approximately
six years);
other-
wise, to conserve
the lithium battery, move
P7 to the OFF position.
When packaging
the PCTU,
use only a non-conductive
material
enclosure,
such as plain paper.
Conductive
material
can cause the inter-
nal battery
to discharge
and erase mem-
ory in the PCB.
3.30 PCTU Wiring
3.31
Refer to MOH/BGM
Wiring Diagram,
Section
200-096-208,
for PCTU wiring/interconnecting
de-
tails.
3.40 PCTU Programming Overview
3.41
After
initially
installing
a new and unused
PCTU,
all on-board
RAM memory
needs
to be
erased
by running
Programs
90 and 92. If RAM
contains
configuration
or feature
data from previ-
ous programming
that should be retained,
either do
not run these
programs
or use them selectively.
See the Programming
Procedures,
Section
200-
096-300.
3.42
The following
parameters
may be specified,
through
programming,
for the PCTU:
Program 03
l
Specify code 91 to indicate
a normal
PCTU.
l
Specify code 92 or 93 to indicate
a PCTU with
DTMF
Receiver
Unit (CRCU-4
or CRCU-8,
re-
spectively)
option installed.
NOTE:
Codes 9 1,92, and 93 apply to both the PCTU
and PCTUSl.
Program 12
l
Select the seize time of the CRCU
circuit.
4 ELECTRONIC
TELEPHONE
INTERFACE
UNIT (PEKU)
.
4.00 General
4.01
The
Electronic
Telephone
Interface
Unit
(PEKU)
provides
eight
ports for electronic
tele-
phones.
Depending
on system configuration,
DK24
can support
up to four PEKUs with PCTU (1 or 2)
and three PEKUs with PCTUSI
; DK56 can support
up to eight PEKU PCBs, and DK96 up to twelve
PEKU PCBs.
4.02
The number
of electronic
telephones
that can
be connected
to PEKU PCBs in a system depends
on the series of telephones
used. This is due to
power capacity.
It is recommended
that the current
6500-series
be used,
because
this series
con-
sumes
the least amount
of power. The maximum
number
of 6500-series
electronic
telephones
al-
lowed in DK24 is 32, in DK56 is 64, and in DK96 is
96. If using an electronic
telephone
series other
than, or mixed with, the 6500-series,
see the con-
figuration
chapter,
Section
200-096-204,
work-
sheet 7.
4.03
The PEKU can be configured
for Off-hook
Call Announce
(to receive OCA calls) by installing
an Off-hook
Call Announce
Unit (EOCU).
It can
also be configured
to support
a DSS console,
a
Door
Phone/Lock
Control
Box (HDCB),
and an
external
Background
Music (BGM) source connec-
tor. DSS consoles,
HDCBs,
and the BGM source,
are wired
directly
to the PEKU
and
require
no
additional
hardware,
but do require specific
ports/
circuits.
4.04
PEKU controls
and interface
connectors
are
shown
in Figure 6-4 and described
in Table 6-B.
4.10 PEKU Hardware Options
4.11
The PEKU supports
the following
hardware
options:
Internal Options
l
Off-hook
Call Announce
Unit (EOCU)
External Options
I
l
DSS console
l
Door Phone/Lock
l
BGM source connection
6-6