Toshiba STRATA DK24 Manual page 188

Hide thumbs Also See for STRATA DK24:
Table of Contents

Advertisement

NOTE:
CO lines must be enabled
in
Program 78
for
the NT pulsating
relay function.
3) Access
Programs
87, 88, and 89 to set the
CO lines that will activate the relay (when the
system
is in the NIGHT
mode).
4) Access
Program
39 to program
a Night
Transfer
button
(NT1
or NT2)
on all tele-
phones that are to transfer the system into the
NIGHT
mode.
5) Access Programs
29-1 N 29-4 to program
a
Night Transfer
button (NT1 or NT2) on all DSS
consoles
that are to transfer
the system
into
the NIGHT
mode.
NOTE:
Program29-4is
notavailable
when a PCTUSI
PCB is installed.
6) If tenant operation
is required, access Program
15 to set the CO lines for tenant
1 (m)
or
tenant
2 (m)
operation.
7A) Set the PI 1 jumper
plug on the PIOU or PEPU
to the MAKE or BREAK position,
as required:
l
MAKE-Shorts
the normally
open con-
tacts (pins 9 and 34) when the night relay
is activated.
l
BREAK-Opens
the
normally
closed
contacts
(pins 9 and 34) when the night
relay is activated.
7B) Solder the jumper
W2 on the PIOUS
to the
MAKE or BREAK
position,
as required:
l
MAKE-Shorts
the normally
open con-
tacts
(NHT
and NHR)
when
the night
relay is activated.
l
BREAK-Opens
the
normally
closed
contacts
(NHT
and
NHR)
when
night
relay is activated.
8) Refer to Figures 8-7 and 8-8 for wiring/inter-
connecting
details.
Connect
the PIOU,
PI-
OUS, or PEPU to the MDF as required
for the
night relay function.
INSTALLATION-PERIPHERALS
SECTION 200-096-208
FEBRUARY 1991
NOTE:
Door phones
programmed
to ring over exter-
nalpage
in night mode
(Program 77-i)
db not
activate
the NT relay.
4.25
MOH
Relay
Control.
Configure
the PIOU,
PIOUS,
or PEPU for the MOH relay function
in
accordance
with the following
steps (refer to Fig-
ures 8-7 and 8-8):
1)
24
2B)
3)
5
Access Program
77-l.
Set LED 05 to ON to
configure
the Night/MOH
relay for the MOH
relay function.
Set the Pll jumper
plug on the PIOU or PEPU
to the MAKE or BREAK
position,
as required:
l
MAKE-Shorts
the normally
open con-
tacts (pins 9 and 34) when any CO line is
on hold.
l
BREAK-Opens
the
normally
closed
contacts
(pins 9 and 34) when any CO
line is on hold.
Solder
the W2 jumper
on the PIOUS to the
MAKE or BREAK
oosition,
as required:
MAKE-Shorts
the normally-open
con-
tacts (NHT and NHR) when any CO line
is on hold.
BREAK-Opens
the
normally
closed
contacts
(NHT and NHR) when any CO
line is in on hold.
Refer to Figures 8-7 and 8-8 for wiring/inter-
connecting
details.
Connect
the PIOU,
PI-
OUS, or PEPU to the MDF as required
for the
MOH relay function.
EXTERNAL
SPEAKER
UNIT (HESB)
OPTIONS
5.00
STRATA
DK systems
provide
three options
utilizing an HESB:
5.01
Loud
Ringing
Bell Option.
The Loud Ring-
ing Bell option allows the voice first or ringing signal
tone to be amplified
without the use of other manu-
facturers'
equipment.
The voice first and signal
tone can be amplified
on all 6500-series
electronic
8-7

Advertisement

Table of Contents
loading

This manual is also suitable for:

Strata dk56Strata dk96

Table of Contents