SANY SY365C LC Operation And Maintenance Manual page 225

Table of Contents

Advertisement

SY365C LC Excavator OMM
7. Clean the area around the hydraulic tank drain plug (4).
8. Place an appropriately sized container under the drain
plug. See "Capacities" on page 5-13.
9. Remove the hydraulic tank drain plug and allow the
tank to drain.
NOTICE!
Dispose of used hydraulic oil properly. Failure
to do so could damage the environment.
10. Replace the O-ring on the hydraulic tank drain plug.
11. Install the hydraulic tank drain plug.
12. Remove fasteners (5) and remove the hydraulic return
filter cover (6).
SANY
Fig. 5-92
Fig. 5-93
Operation and Maintenance Manual — 0420
Maintenance
4
6
5
0004166
5-73

Advertisement