Horizontal Infrared Toaster
IRT-SB-NA-1PS
IRT-SB-NA-3PS
Power off and Unplug the unit
1
Failure to disconnect power
from the unit before servicing
could result in severe bodily
injury or death. The ON/OFF
Switch does not disconnect
incoming power to the unit.
Remove the Motor. Reference the motor removal on
2
page 17.
Remove the conveyor assembly from the unit by re-
3
moving (2) Philips screws. Reference the
Remove all insulation from the right side of the
4
conveyor assembly.
Remove (4) nuts on the right side of the conveyor
5
using an 8mm nut driver. Reference the
Remove (2) Philips screws to free the right side panel
6
of the conveyor assembly. Reference the
Slide the conveyor belt off of the assembly. Reference
7
figure 1.
IRT-SB-NA-1PS
IRT-SB-NA-3PS
Remove Wire Belt
WARNING
Red
Arrows.
Blue Arrows.
Green Ar-
#
#
6
5
#
#
6
5
24
#
5
#
5
Figure 1
Printed in USA 12/3/2020
353-567 Rev. B