4.4.17 Analog Trigger

Brief description
The output is switched on, if the analog value exceeds a
parameterizable on threshold. The output is switched off if
the analog value falls below the parameterizable off thresh-
old (hysteresis).
Symbol in
LOGO!
Gain and Offset parameters
Refer to the information in Section 4.3.6 on the Gain and
Offset parameters.
LOGO! Manual
A5E00067781 01
Connection
Input Ax
Parameter Par:
, , SW ,
SW
Output Q
LOGO! Functions
Description
At the output Ax, apply the
analog signal to be evalu-
ated.
Use the connectors I7 (AI1)
or I8 (AI2).
0-10 V corresponds to
0-1000 (internal value).
: Gain in %
Value range 0..1000 %
: Offset
Value range
SW : on threshold
Value range
SW : off threshold
Value range
Q is set or reset depending
on the threshold values.
999
19990
19990
115