Connecting Logo!'S Inputs - Siemens LOGO! 24RC Manual

Table of Contents

Advertisement

Installing and Wiring LOGO!

2.2.2 Connecting LOGO!'s Inputs

Prerequisites
Connect sensors to the inputs. The sensors may be push-
buttons, switches, photoelectric barriers, daylight control
switches etc.
Sensor attributesfor LOGO!
Circuit state 0
Input current
Schaltzustand 1
Input current
Circuit state 0
Input current
Circuit state 1
Input current
Circuit state 0
Input current
Circuit state 1
Input current
14
LOGO! 12/24 RC/RCo
I1 ... I6
< 5 V DC
< 5 V DC
< 1.0 mA
< 0.05 mA
> 8 V DC
> 8 V DC
> 1.5 mA
> 0.1 mA
LOGO! 24
LOGO! 230
RC/RCo (AC)
RC/RCo
< 5 V AC
< 40 V AC
< 1.0 mA
< 0.03 mA
> 12 V AC
> 79 V AC
> 2.5 mA
> 0.08 mA
LOGO! 12
LOGO! 24
RCL
< 4 V DC
< 5 V DC
< 0.5 mA
< 1.5 mA
> 8 V DC
> 12 V DC
> 1.5 mA
> 4.5 mA
I7, I8
I1 ... I6
< 5 V DC
< 1.0 mA
> 8 V DC
> 1.5 mA
LOGO! 24
L
RCL...
< 5 V DC
< 1.5 mA
> 12 V DC
> 4.5 mA
LOGO! 24
I7, I8
< 5 V DC
< 0.05 mA
> 8 V DC
> 0.1 mA
LOGO! 230
RCL...
< 40 V AC
< 0.03 mA
> 79 V AC
> 0.08 mA
LOGO! Manual
A5E00067781 01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents