Applications

8.2.4 Special Features and Enhancement Options

Functionality and user friendliness can be improved in the
following ways, for example:
You can connect an additional control switch: Open –
Automatic – Closed (O-A-C)
You can connect a buzzer to one of LOGO!'s outputs to
indicate when the door is about to close.
You can include time and direction-dependent enabling
of door opening (so that it only opens during shop open-
ing hours or only from the inside to the outside after
closing time).

8.2.5 Enhanced LOGO! 230RC Solution

Wiring of the enhanced LOGO! solution
L1
N
160
S1
B1
B2
L1 N
I1 I2 I3 I4 I5 I6
SIEMENS
LOGO!
230RC
Q1
Q2
Q3
K1
K2
H1
Open
Close
Buzzer
O-A-G
S3
S2
Q4
LOGO! Manual