LOGO! Functions
Parameter inputs
There some inputs at which you do not apply signals.
Instead, you parameterize the function block with certain
values.
Par (parameter):
This input is not wired. Here you set parameters for the
block.
T (time):
This input is not wired. Here you set times for a block.
No (number):
This input is not wired. Here you set time bases.
P (priority):
This input is not wired. Here you set priorities.
4.3.2

Time Response

Parameter T
With some of the special functions it is possible to parame-
terize a time value T. When specifying the time, note that
the values to be entered depend on the time base set:
Time Base
s (seconds)
m (minutes)
h (hours)
B01:T
T=04.10h+
74
_ _
:
_ _
1
Seconds
:
Minutes
:
Seconds
Hours
:
Minutes
Setting the time T for 250 minutes:
Unit hours (h):
04.00 hours
240 minutes
00.10 hours
+10 minutes
=
250 minutes
/
seconds
100
LOGO! Manual
A5E00067781 01