3.2 UART setting

* Baud Rate: Set the UART baud rate. Different CAN converters have different upper
baud rate limits.
* Data Bit: Set the UART data bit, the CAN converters support four data bit settings.
* Stop Bit: Set the UART stop bit, the CAN converters support two data bit settings.
* Parity Bit: Set the UART parity bit check, the CAN converter supports three data bit
settings.
* Add Checksum: Set the CAN converter to enable the checksum for the UART
command string, and only supports the communication mode is the normal mode. If
the function be set to enable, when the UART command string is transceived or
received need to add two check characters to be checksum after the string as below
figure below. In addition, please refer to section 4.1 for the calculation method of
the checksum.
* Error Response: Set the CAN converter to enable the error response for the UART
command string which in chapter 4, and the function only supports the
communication mode is the normal mode. If the function be set to enable, the
module will respond with an error code when the user enters an incorrect UART
command string. In addition, please refer to section 4.13 for error codes.
I-7530, I-7530A, I-7565, I-7530-FT, tM-7530, tM-7530A, tM-7565 User Manual Version 1.6
Copyright © 2018 ICP DAS Co., Ltd. All Rights Reserved E-mail: service@icpdas.com
40