 User-defined: This function allows the user to define the ending character,
and only suppout tM-7530, tM-7530A and tM-7565. Among them, "User
Defined1" and "User Defined2" can set 1 end character an d 2 end characters
respectively as beolw figure, when "User Defined2" is selected and the end
characters are set to 0x0D and 0x0A, when the CAN converter receive 0x0D
and 0x0A, and the received data will be added to the end character and then
sent to the other side.
* Pair Connection Command Timeout: Set the waiting time when receiving data,
and only suppout tM-7530, tM-7530A and tM-7565. When the CAN converter
receives a byte data, it will wait for this time to confirm whether new data has been
received. If no new data is received after this time will determined that the data is
received completely, and will send the data to the other side.
"CAN Timeout" can set the timeout time for converting CAN data to UART data, and
"UART Timeout" can set the timeout time for converting UART data to CAN data. If the
user wants to send the data immediately, the value can be set to 0.
Among them, the function of "UART Timeout" will only work when "End Characters
of UART Commands" is set to "None". In addition, about the application of the pair
connection mode, please refer to section 5.6.
I-7530, I-7530A, I-7565, I-7530-FT, tM-7530, tM-7530A, tM-7565 User Manual Version 1.6
Copyright © 2018 ICP DAS Co., Ltd. All Rights Reserved E-mail: service@icpdas.com
49
Page:

Advertisement

Table of Contents
loading

This manual is also suitable for:

I-7530I-7530aI-7565I-7530-ftTm-7530Tm-7530a ... Show all

Table of Contents