3.5.2
Connecting the Antistatic Wrist Strap
Caution – The drive array is sensitive to static electricity. To prevent damage to the
unit, connect an antistatic wrist strap to your wrist and to the chassis.
1. Attach the adhesive copper strip to a metal surface of the chassis.
2. Wrap the other side of the wrist strap twice around your wrist, with the adhesive
side against your skin.
FIGURE 3-7
3.5.3
Removing a Drive
1. Identify all volumes or applications that use the failed drive.
If the volumes are mirrored or RAID 5 protected, the drive can be replaced without
taking the volume down. Otherwise all input/output to the drive must be stopped
using the appropriate commands.
3-8
Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000
Attaching the Wrist Strap
Need help?
Do you have a question about the StorEdge MultiPack-FC and is the answer not in the manual?