Sun StorEdge MultiPack-FC ™ Installation, Operation, and Service Manual Sun Microsystems, Inc. 901 San Antonio Road Palo Alto, CA 94303 U.S.A. 650-960-1300 Part No. 806-3960-10 August 2000, Revision A Send comments about this document to: docfeedback@sun.com...
Page 2
Sun, Sun Microsystems, the Sun logo, AnswerBook2, docs.sun.com, SunVTS, StorEdge, Sun Enterprise, and Solaris are trademarks, registered trademarks, or service marks of Sun Microsystems, Inc. in the U.S. and other countries. All SPARC trademarks are used under license and are trademarks or registered trademarks of SPARC International, Inc.
Page 3
FCC radio frequency emission limits. Networking connections can be made using unshielded twisted-pair (UTP) cables. Modifications: Any modifications made to this device that are not approved by Sun Microsystems, Inc. may void the authority granted to the user by the FCC to operate this equipment.
Page 4
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada. BSMI Class A Notice The following statement is applicable to products shipped to Taiwan and marked as Class A on the product compliance label. Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 6
Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 7
Follow all cautions and instructions marked on the Do not make mechanical or electrical modifications to the equipment. equipment. Sun Microsystems is not responsible for Ensure that the voltage and frequency of your power regulatory compliance of a modified Sun product.
Page 8
Achtung – Gefährliche Spannungen. Anweisungen befolgen, um Stromschläge und Verletzungen zu vermeiden. Ein – Setzt das System unter Wechselstrom. viii Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 9
Wartezustand. Änderungen an Sun-Geräten. Nehmen Sie keine mechanischen oder elektrischen Achtung – Nicht alle Netzkabel haben die Änderungen an den Geräten vor. Sun Microsystems, gleichen Nennwerte. Herkömmliche, im übernimmt bei einem Sun-Produkt, das geändert wurde, Haushalt verwendete Verlängerungskabel keine Verantwortung für die Einhaltung behördlicher besitzen keinen Überlastungsschutz und sind...
Page 10
Attention: – présence de tensions normes SELV. dangereuses. Pour éviter les risques d’électrocution et de danger pour la santé physique, veuillez suivre les instructions. MARCHE – Votre système est sous tension (courant alternatif). Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 11
Connexion du cordon d’alimentation. Normativas de seguridad El siguiente texto incluye las medidas de seguridad que se deben seguir cuando se instale algún producto de Sun Attention: – les produits Sun sont conçus Microsystems. pour fonctionner avec des alimentations monophasées munies d’un conducteur neutre mis à...
Page 12
70Db(A). Cumplimiento de la normativa SELV El estado de la seguridad de las conexiones de entrada/ salida cumple los requisitos de la normativa SELV. Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 13
La siguiente advertencia se aplica solamente a equipos con un interruptor de encendido que tenga una posición "En espera": Precaución – El interruptor de encendido de este producto funciona exclusivamente como un dispositivo de puesta en espera. El enchufe de la fuente de alimentación está diseñado para ser el elemento primario de desconexión del equipo.
Page 14
Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 15
Dennis P. Symanski DATE John Shades DATE Manager, Product Compliance Quality Assurance Manager Sun Microsystems, Inc. Sun Microsystems Scotland, Limited 901 San Antonio Road, M/S UMPK15-102 Springfield, Linlithgow Palo Alto, CA 94303, USA West Lothian, EH49 7LR Scotland, United Kingdom Tel: 650-786-3255...
Page 16
Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 18
Removing the Drive Cage and Backplane 3-17 Removing and Replacing the LED Clip and Cable 3-24 3.8.1 Removing the Major Assemblies 3-25 3.8.2 Removing the LED Clip 3-27 xviii Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 19
3.8.3 Replacing the LED Clip and Cable 3-27 3.8.4 Reassembling the MultiPack-FC 3-28 A. Product Specifications A-1 Electrical Specifications A-2 Physical Specifications A-2 Environmental Specifications A-3 Safety Standards A-3 Electromagnetic Interference A-4 Electrical Disturbances A-4 Contents...
Page 20
Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Preface The Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual provides information and procedures about installing, operating, and servicing the Sun StorEdge™ MultiPack-FC hard drive array. Using UNIX Commands ® This document may not contain information on basic UNIX commands and procedures such as shutting down the system, booting the system, and configuring devices.
Page 22
Shell Prompts Shell Prompt C shell machine_name% C shell superuser machine_name# Bourne shell and Korn shell Bourne shell and Korn shell superuser xxii Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 23
Ordering Sun Documentation Fatbrain.com, an Internet professional bookstore, stocks select product documentation from Sun Microsystems, Inc. For a list of documents and how to order them, visit the Sun Documentation Center on Fatbrain.com at: http://www.fatbrain.com/documentation/sun...
Page 24
Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Section 1.4 “Software Requirements” on page 1-9 Product Description The Sun StorEdge MultiPack-FC is a high performance hard drive data storage system with a Fibre Channel interface. It supports a maximum of six hard drives of the 25.4-mm (1.0-in.) x 88.9-mm (3.5-in.) form factor. The system has one high speed serial data connection (HSSDC) connector and one gigabit interface converter (GBIC) connector.
Page 26
MultiPack-FC, Front View FIGURE 1-1 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 27
Lock box Power supply fans Fibre Channel input/output (HSSDC connector) AC power on/off switch Fibre Channel input/output (GBIC connector) AC power inlet Box ID switch MultiPack-FC, Back Panel Details FIGURE 1-2 Chapter 1 Installation...
Page 28
MultiPack-FC Locking Drive Access Panel FIGURE 1-3 MultiPack-FC Stationary Side Panel FIGURE 1-4 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Note – For Fibre Channel functionality, the host or host adapter to which you connect your MultiPack-FC unit must use the Fibre Channel interface. Physical Placement The MultiPack-FC unit weighs from 12.7 to 14.7 kg (28.0 to 32.5 lb.) when fully equipped with six disk drives.
Note – For drive slot numbering, see FIGURE 2-3 and FIGURE 2-4. The formula for target IDs (target addresses) is: Box ID * 8 + Slot ID = Target ID Target IDs TABLE 1-1 Box ID Drive Slot Target ID Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
1.3.3 Connectivity Features The MultiPack-FC does not require external bus termination. A maximum of two MultiPack-FC units can be connected in a daisy chain. You must order optical GBICs and cables separately. 1.3.4 GigaBit Interface Converters Gigabit interface converters (GBICs) are optional products that can be used with MultiPack-FC units.
Software Requirements 1.4.1 Solaris Operating Environment The MultiPack-FC is fully functional with the Solaris 8 operating environment and later releases. Chapter 1 Installation...
Page 34
1-10 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
C H A P T E R Operation This chapter consists of the following sections: Section 2.1 “Front Bezel LEDs” on page 2-2 Section 2.2 “Configuring Drives” on page 2-3 Section 2.3 “Setting the Box ID” on page 2-6 Section 2.4 “Powering On and Off” on page 2-8 Section 2.5 “Daisy Chaining”...
Front Bezel LEDs Power LED Drive LEDs Front Bezel LED Identification FIGURE 2-1 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Drive present, active Amber, Steady Drive present, failed Drive absent Configuring Drives Each Sun StorEdge MultiPack-FC unit is configured with a minimum of two and a maximum of six hard drives that are 25.4-mm (1.0-in.) in height (FIGURE 2-2). Chapter 2 Operation...
Page 38
MultiPack-FC Equipped With Six Drives FIGURE 2-2 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Setting the Box ID On the back of the MultiPack-FC chassis is a box identification (ID) switch (FIGURE 2-5). The box ID number is set at 1 at the factory. Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Box ID switch Box ID Switch Location FIGURE 2-5 2.3.1 Connecting One Unit to the Host 1. Check that the box ID is set to 1 before connecting the unit to the host. 2. Invoke the forcelip operations in Step 3 of Section 2.5 on pages 2-9 and 2-10. 2.3.2 Daisy Chaining Two Units to the Host Note –...
Caution – Always allow 10 seconds between turning off the power and turning it back on again. This prevents possible damage to the power supply assembly components in your system. Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Powering Off the System 2.4.2 Before you can power off the system, you must shut down the operating system. Refer to the Solaris Handbook for Sun Peripherals for specific software instructions on shutting down your operating system. Turn off the power to your system in the following order: a.
Power supply fans Fibre Channel input/output (HSSDC) AC power on/off switch Fibre Channel input/output (Optical GBIC) AC power inlet Box ID switch Sun StorEdge MultiPack-FC Back Panel Details FIGURE 2-7 2-10 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 45
TABLE 2-3 lists symptoms, causes, and troubleshooting solutions for problems that might occur. Troubleshooting the Sun StorEdge MultiPack-FC TABLE 2-3 Then: Action(s): A single drive is not See FIGURE 2-1 for drive LED responding. locations. 1. Amber LED is lit.
Diagnostic Software 2.7.1 SunVTS The SunVTS™ diagnostic software program verifies that the MultiPack-FC unit functions properly. It is used to locate failed field replaceable units (see Chapter 3 “Service”). 2-12 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
2.7.2 probe-scsi-all At the ok prompt, use the probe-scsi-all command to verify that a host system’s Fibre Channel Arbitrated Loop (FC-AL) controller recognizes externally connected Fibre Channel hard drives. ok probe-scsi-all /pci@8,600000/scsi@4 Li D HA --- Port WWN --- ---- Disk description ---- 1 1 210000203700ca6d SEAGATE ST39103FCSUN9.0G01479916015471 8 8 210000000ec90dac FUJITSU MAG3182F SUN18G 08129921B01224 a a 210000000ec91003 FUJITSU MAG3182F SUN18G 08129922B01729...
Page 48
/pci@1f,4000/scsi@3 /pci@1f,4000/network@1,1 /pci@1f,4000/ebus@1 /pci@1f,4000/pci@5/SUNW,qlc@5 /pci@1f,4000/pci@5/SUNW,qlc@4 /pci@1f,4000/pci@5/SUNW,qlc@5/fp@0,0 /pci@1f,4000/pci@5/SUNW,qlc@5/fp@0,0/disk /pci@1f,4000/pci@5/SUNW,qlc@4/fp@0,0 /pci@1f,4000/pci@5/SUNW,qlc@4/fp@0,0/disk /pci@1f,4000/pci@4/SUNW,qlc@5 /pci@1f,4000/pci@4/SUNW,qlc@4 /pci@1f,4000/pci@4/SUNW,qlc@5/fp@0,0 /pci@1f,4000/pci@4/SUNW,qlc@5/fp@0,0/disk /pci@1f,4000/pci@4/SUNW,qlc@4/fp@0,0 /pci@1f,4000/pci@4/SUNW,qlc@4/fp@0,0/disk /pci@1f,4000/scsi@3,1/tape /pci@1f,4000/scsi@3,1/disk /pci@1f,4000/scsi@3/tape /pci@1f,4000/scsi@3/disk System Recognition of External Drives, Part 1 FIGURE 2-9 2-14 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
C H A P T E R Service This chapter consists of the following sections: Section 3.1 “Removable Parts Breakdown” on page 3-2 Section 3.2 “Required Tools” on page 3-3 Section 3.3 “Field Replaceable Units” on page 3-3 Section 3.4 “Opening the Drive Access Panel” on page 3-6 Section 3.5 “Removing and Replacing a Drive”...
MultiPack-FC Removable Parts Breakdown FIGURE 3-1 MultiPack-FC Removable Parts Breakdown Key TABLE 3-1 FIGURE 3-1 Reference Number Part Name Chassis Backplane LED cable LED clip Drive cage Hard drive Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
MultiPack-FC Removable Parts Breakdown Key TABLE 3-1 FIGURE 3-1 Reference Number Part Name Drive access panel Daughter board clip Daughter board Power supply Required Tools Antistatic wrist strap Electrostatic discharge (ESD) mat for drives No. 2 Phillips screwdriver Field Replaceable Units Hard drive (FIGURE 3-2) Chassis with plastic panels Power supply (FIGURE 3-3)
Page 54
Hard Drive With Bracket FIGURE 3-2 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 55
Removing the Power Supply FIGURE 3-3 Drive Cage With Backplane FIGURE 3-4 Chapter 3 Service...
Opening the Drive Access Panel FIGURE 3-5 Removing and Replacing a Drive 3.5.1 Hot Plugging Drives Hot-plugging allows drives to be removed and replaced without turning power off to the MultiPack-FC. Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 57
Caution – Drives should not be pulled out randomly. If the drive is active, you must stop that activity before removing the drive. This can be done without shutting down the operating system or powering off the MultiPack-FC unit. The Sun MultiPack-FC hardware supports hot-plugging drives, but there are software considerations that must be taken into account.
If the volumes are mirrored or RAID 5 protected, the drive can be replaced without taking the volume down. Otherwise all input/output to the drive must be stopped using the appropriate commands. Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 59
2. Use the luxadm remove_device command to remove the disk from the Fibre Channel Arbitrated Loop (FC-AL). This command is interactive and will prompt you to physically remove the drive. For example: # luxadm remove_device /dev/rdsk/c3t8d0s2 WARNING!!! Please ensure that no filesystems are mounted on these device(s).
Page 60
Opening the Drive Access Panel FIGURE 3-8 4. Remove the drive and place it on an antistatic mat. 3-10 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 61
Opening the Drive Bracket FIGURE 3-9 Removing a Drive FIGURE 3-10 Chapter 3 Service 3-11...
Slide the drive into the slot with the handle released. Once you have inserted the drive as far as it will go, push down on the handle to secure it. 3. Reinstall the drive access panel and lock it. 3-12 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
4. Press Return to complete the luxadm insert_device command. For example: Hit <Return> after inserting the device(s). Device: /dev/rdsk/c3t8d0s0 Logical Nodes under /dev/dsk and /dev/rdsk: c3t8d0s0 c3t8d0s1 c3t8d0s2 c3t8d0s3 c3t8d0s4 c3t8d0s5 c3t8d0s6 c3t8d0s7 Removing and Replacing the Power Supply 3.6.1 Removing the Power Supply 1.
Page 64
(FIGURE 3-11). 4. Open and remove the drive access panel. Lock box Screw Screw Screw Screw Lock Box and Power Supply Screw Locations on Back Panel FIGURE 3-11 3-14 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
5. Pull the power supply completely out of the chassis. Removing the Power Supply FIGURE 3-12 3.6.2 Replacing the Power Supply 1. Align the power supply at the back of the unit so that the connector on the power supply aligns with the connector on the daughter board (FIGURE 3-13). Chapter 3 Service 3-15...
Page 66
2. Insert the power supply into the unit until the edges of the power supply are flush against the edge of the chassis. 3. Replace the lock box and screws that secure the power supply to the chassis. 3-16 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Lock box Screw Screw Screw Screw Lock Box and Power Supply Screw Locations on Back Panel FIGURE 3-14 4. Reconnect the Fibre Channel cable(s) and power cord. 5. Turn on the power to your system. See Section 2.4.1 “Powering On the System”. Removing and Replacing the Drive Cage and Backplane 3.7.1...
Page 68
Fibre Channel Cable Connectors, Power Switch, and Power Inlet Locations FIGURE 3-15 3. Turn the key lock and open the drive access panel. Opening the Drive Access Panel FIGURE 3-16 3-18 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 69
4. Remove all the drives. Removing a Drive FIGURE 3-17 Note – Make careful note which drive is removed from which slot (especially the boot drive). This will help you to replace the drives in the proper order. Chapter 3 Service 3-19...
Page 70
Two screws on the back panel near the I/O connectors (FIGURE 3-18, A and B) Two screws on the left side of the drive cage (FIGURE 3-19) Two screws on the bottom of the chassis (FIGURE 3-19) 3-20 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 71
Drive Cage and Chassis Bottom Screws FIGURE 3-19 Chapter 3 Service 3-21...
Page 72
7. Remove the daughter board and its plastic clip from the drive cage. Removing the Daughter Board Clip and the Daughter Board FIGURE 3-20 8. Remove the LED cable from the LED clip (FIGURE 3-19). 3-22 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 73
9. Pull the drive cage and backplane assembly upward until the assembly clears the enclosure. Remove the assembly from the enclosure. Removing the Drive Cage and Backplane Assembly FIGURE 3-21 10. Reassemble the system. a. Replace the drive cage and backplane assembly. Slide the assembly towards the back of the system so that the screw holes align.
Caution – The power must be turned off and the power cord must be removed from the MultiPack-FC before the parts removal procedures are attempted. Caution – Remove all I/O cables from the MultiPack-FC before the parts removal procedures are attempted. 3-24 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
LED clip LED cable Daughter board clip Daughter board MultiPack-FC Removable Parts Breakdown FIGURE 3-22 3.8.1 Removing the Major Assemblies 1. Turn the MultiPack-FC enclosure so that it rests on its stationary side panel, with the locking drive access panel facing you. 2.
Page 76
Two screws on the bottom of the chassis Two screws on the back of the chassis near the I/O connectors (FIGURE 3-24, A and B) Two screws by the left side of the drive cage 3-26 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Removing the Drive Cage and the LED Cable From the LED Clip FIGURE 3-24 3.8.2 Removing the LED Clip 1. Remove the LED cable from the LED clip (FIGURE 3-24). 2. Press down on the two clip tabs. 3. Unhook the clip from the chassis. 3.8.3 Replacing the LED Clip and Cable 1.
3. Install the daughter board into the main logic board (FIGURE 3-26). 4. Install the daughter board clip onto the daughter board. Tighten the screws on the clip to the drive cage (FIGURE 3-26). 3-28 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 79
Replacing the Daughter Board and the Daughter Board Clip FIGURE 3-26 5. Connect the LED cable to the LED clip. Blue strand Connecting the LED Cable to the LED Clip FIGURE 3-27 6. Install the power supply, and tighten the corner screws and lock box. 7.
Page 80
3-30 Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Page 81
A P P E N D I X Product Specifications This appendix consists of the following sections: Section A.1 “Electrical Specifications” on page A-2 Section A.2 “Physical Specifications” on page A-2 Section A.3 “Environmental Specifications” on page A-3 Section A.4 “Safety Standards” on page A-3 Section A.5 “Electromagnetic Interference”...
TABLE A-2 Height 240-mm (9.45-in.) Width 197-mm (7.76-in.) Depth 452-mm (17.80-in.) Weight: Without drives 8.6 kg (19.0 lb) With six 25.4 mm (1.0 in.) height drives 12.7 kg (28.0 lb) Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Environmental Specifications Environmental Specifications TABLE A-3 Temperature Operating 5°C to 40°C Nonoperating -40°C to 60°C Relative Humidity Operating 20% @ 40°C to 80% @ 31°C Nonoperating 5% to 93% Vibration Operating 0.2 G (0~Pk) Swept Sine Nonoperating 1.0 G (0~Pk) Swept Sine Altitude Operating 3,000 meters @ maximum operating temperature derated 1.8°C per...
VCCI Class 2 Japan CSA C108.8-M1983 class B Canada Electrical Disturbances Electrical Disturbances TABLE A-6 Specification Comments EC1000-4-2 Electrostatic discharge (ESD) EC1000-4-3 Radiated electromagnetic field EC1000-4-4 Electrical fast transient EC1000-4-5 Surge Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000...
Need help?
Do you have a question about the StorEdge MultiPack-FC and is the answer not in the manual?