2.4
Powering On and Off
This section describes how to turn on and off the power to your Sun StorEdge
MultiPack-FC unit when it is connected to a desktop host.
FIGURE 2-6
2.4.1
Powering On the System
Caution – Perform the appropriate procedure in Section 2.3 "Setting the Box ID" on
pages 2-6 and 2-7 before performing the following power-on procedure.
1. Turn on the power to the data storage peripheral devices connected to the host in
this order:
a. Last device on the daisy chain
b. Other peripheral devices
2. Turn on the power to the monitor.
3. Turn on the power to the host.
Caution – Always allow 10 seconds between turning off the power and turning it
back on again. This prevents possible damage to the power supply assembly
components in your system.
2-8
Sun StorEdge MultiPack-FC Installation, Operation, and Service Manual • August 2000
AC power on/off switch
|
0
AC power inlet
Power Switch and Inlet Locations on the MultiPack-FC