Front Panel - Xantrex XPLORE 120A 12V Owner's Manual

Table of Contents

Advertisement

Front Panel

Front Panel
Figure 3 Front Panel
A
B
C
D
ELECTRICAL SHOCK HAZARD
Replace the wiring compartment cover before turning on
n
power to this equipment.
Use a torque screwdriver to tighten both the captive nut
n
panel screws to 5 in-lb (0.56 N-m) torque to ensure a
required tool access to the wiring compartment.
Failure to follow these instructions can result in death, serious
injury, or equipment damage.
6
E
WARNING
Item
A
Mounting flanges are used to permanently install the product.
B
Onboard status LED panel (see Onboard Status LED Panel on
page 8 for more information) for monitoring charging status for the
three banks.
C
Wiring compartment cover protects the DC and AC terminals,
as well as accessory ports.
Remove and replace when installing cables. Also provides access
to the AC and DC fuses in the event of an AC overload and
accidental reverse polarity condition, respectively.
D
Captive nut panel screws for loosening and securing the wiring
compartment cover.
E
Air vent for air exchange/circulation.
ELECTRICAL SHOCK HAZARD
Disconnect the batteries and AC power before opening the wiring
compartment cover.
Failure to follow these instructions will result in death or serious
injury.