Insinger GalleyMaster 135-LH-E Technical Manual page 18

Galleymaster series
Hide thumbs Also See for GalleyMaster 135-LH-E:
Table of Contents

Advertisement

!
WARNING:
Float switches, probes and heating
elements must be cleaned daily.
Accumulations of grease, minerals or
debris will cause faulty operation of
detergent monitoring and heating
systems. Use Scotch-Brite or
equivalent cleaning pads on heavy dirt.
Use a small wire or pin to clean mineral accumulations
from the final hot rinse nozzles.
Replace the wash and rinse spray manifolds:
1. Slide the hub of each manifold over the boss on the
vertical discharge tube. The slots in the manifold hub
must engage the pins in the boss of the vertical dis-
charge tube.
2. When the slots in the manifold hub are fully engaged
over the pins, rotate the plunger head 90°. The plunger
pin must enter into the hole in the boss.
CAUTION:
The plunger pin must enter into the hole
in the boss of the vertical manifold to lock the
manifold in position.
If the pin is not in the hole, the manifold will come
off when the pumps are started.
Replace all removed parts in reverse order. Re-install
wash and rinse pump suction strainers and overflow
tubes.
þ
NOTE:
Center curtain has a yellow stripe.
Enter and exit curtains have red stripes.
Doors should remain open to allow interior surfaces to
dry. Drains should be closed.
GalleyMaster DOC Revision 2006
PART 3 CLEANING INSTRUCTIONS
17
www.insingermachine.com 800-344-4802