2.4

Power supply function

CPC batteries chargers with a charging program with start voltage 0 V* can also be used without a
battery to supply DC consumers up to the maximum capacity of the battery charger. In this case it must
be noted that the output voltage is reduced after a short time from the higher main charging voltage to
the lower maintenance charging voltage.
This allows vehicles to be supplied with voltage even when the battery has been removed, thus avoiding
the time-consuming and tedious re-programming of customer settings in the on-board computer and
radio system.
LEAB can equip all CPC battery chargers with the suitable power supply program* for exclusive use as a
power supply. Please contact LEAB Service in this case.
Charging programs must be stated in your order for the CPC battery charger so that they can be installed
in the battery charger.
* Optional extra
Power supply function is only available for devices with start voltage 0 V or with
special power supply program.
The power supply output is resistant to short-circuit and overload, but longer short-
circuit should still be avoided to prevent the charging cable and LEAB CPC becoming
too hot.
The optional power supply program is also suitable for pre-loading exhaustively
discharged batteries which are no longer detected by a battery charger for a few
hours or for regenerating them.
If you would like to use the LEAB CPC in combination with diode distributors or the
charging current distributor LEAB CDB, you must always choose a charging
characteristic with 0 V start voltage.