Optional: Activate Bypass Function; Optional: Connect Remote Led Display; Optional: Change The Charging Current Distribution - LEAB CDR 12/24 V User Manual

Battery isolator
Hide thumbs Also See for CDR 12/24 V:
Table of Contents

Advertisement

7 Installation

7.1 Optional: Activate bypass function

The bypass function (permanently ON) is used to charge the starter battery
with the auxiliary battery if the voltage of the starter battery is too low. The
voltage detection through PIN 5 (GND) is deactivated so that the CDR distrib-
utes charging current at any voltage.
To use the function, carry out the following step:
1 Switch the plug contact PIN 4 to ground.
ð The function is activated.

7.2 Optional: Connect remote LED display

An external LED can be connected and used as a remote display to detect
whether the device is conducting current.
To install the function, perform the following step:
NOTE! External LED: Output 5 V, max. 5 mA. Not included in the scope of de-
livery.
1 Connect the plug contact PIN 1 to the input of an external LED.
2 Connect the other terminal of the external LED to ground.
ð The function is installed.

7.3 Optional: Change the charging current distribution

The CDR can distribute the charging current both bidirectionally and unidirec-
tionally. The factory default setting is bidirectional charging current distribu-
tion in two directions.
To change the direction of the charging current distribution to unidirectional,
carry out the following step:
1 Switch the plug contact PIN 2 to ground.
ð The charging current distribution is unidirectional from screw terminal 1 to
screw terminal 2.
10
LEAB Automotive GmbH
LEAB Automotive GmbH
Thorshammer 6
24866 Busdorf

Advertisement

Table of Contents
loading

This manual is also suitable for:

1072001001

Table of Contents