4.1

CPC connections

Neutrik
connection
230V
Fig. 5 View of CPC from the back, connection side
4.2
Installation site
The following environmental conditions must be given if you want to install the battery charger for
stationary use:
Choose a dry and dust-free spot, not too hot, for installation.
The LEAB CPC can be attached horizontally to a level panel as well as horizontally or
vertically to a wall.
Optimum cooling is achieved with the LED side facing downwards.
Make sure there is sufficient and unobstructed cooling air flow so that the heat
produced can be dissipated safely.
Do not install the device directly next to or above inflammable materials.
Never install the battery charger in the direct vicinity of open wet cell batteries. The
acid vapours produced during charging can corrode and thus destroy the PCB and
other components.
Do not use a charging cable with a cross-section smaller than the one delivered with
the device.
Protect your battery charger from excessive heat impact. This reduces performance
and can shorten the service life.
Heed the installation guidelines for other devices (e.g. radio-controlled devices) to
avoid mutual influence.
Never charge with the charging characteristic set incorrectly. The battery can
become damaged.
All manuals and user guides at all-guides.com
LEAB Automotive -CPC
-
+
+
-
Connection
Connection
plus
minus
charging
charging
cable
cable
LEAB Automotive GmbH
RJ45
RJ45
connection CBL
connection
relay (not
sensor cable
1600W)
RJ45
connection
remote display