LEAB 600W Series User Manual page 8

Compact professional charger, microprocessor controlled battery charger
Table of Contents

Advertisement

in this manual for information about attaching and releasing the plug-type connections as well as
assembly instructions for preparing new connection cables.
Starting charging
Connect the mains plug to a Schuko socket in your building installation, thus switching the CPC battery
charger on. After the device has been connected to the mains, the operational LEDs start to flash red for
2 seconds while the battery charger checks whether or not a battery is connected.
If the LED lights up orange, charging is taking place according to the set program.
Never switch the battery charger on until the connection to the battery has been
established. Otherwise a fault message will be issued and the battery will not be
charged.
No charging takes place as long as the red LED lights up or flashes.
Battery voltage 12 V (one battery)
After a few seconds the CPC starts in the selected program and automatically charges the connected
battery until it is fully charged. If the orange setting LED and the red Error LED are flashing alternately
despite correct voltage, please check the battery voltage. If the voltage is less than 8 V the CPC will not
start charging for safety reasons, in order to avoid potential hazards caused by exhaustively discharged
batteries*.
As soon as the battery is fully charged, the LED display changes from orange to green and the charging
voltage is reduced to maintenance charging. The battery can now be disconnected or remain connected
to the battery charger until it is used. The CPC ensures that the battery remains fully charged in the
meantime, independently of the time involved.
* Only with charging program with start voltage > 0 V.
Choose the correct battery type Standard (for wet cell batteries) or Gel/AGM (for
sealed lead batteries using gel or AGM technology).
correctly in this case.
Individual batteries with a voltage of less than approx. 8 V will no longer be charged
in the charging setting of the CPC for safety reasons: Exhaustively discharged
batteries must be pre-charged for several hours using a power supply (charging
program with start voltage 0 V even charges exhaustively discharged batteries).
Page - 8 -