Figure 49: Overview – Status Details of the selected decoder output 1
8.
In the "IP" block you can view the current settings of the input streams over IP (Some IP settings can be set up
under Codec Settings→Codec→Input Sources, see section 11 "Preset Input Sources" on page 29).
The following abbreviations are used for the configured coder parameters:
Bitrate – bit rate of the incoming IP packets (> than Audio bitrate because it includes the IP Header)
Jitter – packet jitter of the incoming IP stream
Missed – the number of the lost/missing packets
PER – packet error rate of the input stream
Reordered – the number of the carried out reorderings of the IP packets
FEC – the current FEC matrix in the stream
Recov. – the number of the recovered packets
Unrecov. – the number of the unrecoverable packets
9.
To monitor the current outputting audio signal over headphone, set up the headphone interface under
Interface Settings→Headphone (see section 17.2 "Headphone" on page 88).
10. Under Status→Log you can call up information about the decoder status, device operation, output status, data
distribution and errors since the last event log deleting. A list with a description of the events with the
timestamps is displayed in this menu (see section 20.5, "View the Log" on page 106, Figure 88).
NOTE: Configure alarm monitoring under System Settings→Alarm (see section 15.2). If the alarm
monitoring for any parameter is deactivated, no information about the corresponding error will be
shown in the log.
To invert the GPOs and see the status of the switched GPO in case of a triggered alarm, open the
menu Interface Settings→GPO and see step 4. on page 91 in section 17.4 "GPO".