If Filter Selection; D If Filter Selection - Icom IC-7000 Instruction Manual

Hf/vhf/uhf all mode transceiver
Hide thumbs Also See for IC-7000:
Table of Contents

Advertisement

5
FUNCTIONS FOR RECEIVE
■ IF filter selection
The transceiver has 3 passband IF filter widths for
each mode.
For SSB and CW modes, the passband width can be
set from 50 to 3600 Hz in 50 or 100 Hz steps. A total of
41 passband widths are available.
For RTTY mode, the passband width can be set from
50 to 2700 Hz in 50 or 100 Hz steps. A total of 32
passband widths are available.
For AM mode, the passband width can be set from 200
Hz to 10 kHz in 200 Hz steps. A total of 50 passband
widths are available.
D IF filter selection
[MENU/GRP]
q Select the desired mode.
w Select M M - - 1 1 .
• Push and hold [MENU/GRP] for 1 sec. once or twice
to select the menu group M M .
• Push [MENU/GRP] momentarily one or more times to
select the menu M M - - 1 1 .
e Push [F-3 F F I I L L ] momentarily several times to se-
lect the IF filter 1, 2 or 3.
• The selected filter number is displayed in the LCD.
• The filter setting window appears and shows the se-
lected passband width and shift frequency. (The filter
setting window can be turned OFF in the display set
mode. (p. 125)
The IF filter for WFM mode is fixed and cannot be
changed.
75
[F-3]
For FM mode, the passband width is fixed and 3 pass-
band widths are available.
For WFM mode, the passband width is fixed at 280
kHz.
The filter selection is automatically memorized in
each mode.
The PBT shift frequencies are automatically memo-
rized in each filter.
Selected IF filter
Passband
width
Shift
frequency
Popup indicator appears
SPCH
TUNER
/LOCK
/CALL
V/M
F-1
1.8
3.5
1
2
10
14
4
5
21
24
7
8
50
144
.
0
XFC
MW
F-2
7
MODE
3
18
FIL
FIL
6
28
GENE
9
430
F-INP
ENT
CE
HM-151

Hide quick links:

Advertisement

Table of Contents
loading