STEP 6: Secure the cables using the Cable Management System
Attached to the top of the unit is the cable management system. The system will accommodate cables up to 2
AWG/35mm
. Start by inserting the cable tiedown into the slotted aluminum rail. Rotate clockwise to lock the
2
cable tiedown into place. For cables up to 6AWG/16mm
with a cable tie. For cables up to 2 AWG/35mm
secure with a cable tie.
Note: For cables up to 2 AWG/35mm
cable tie between the aluminum rail and the cable
tie down.
Note: Alternate and stagger the cable tie downs to maximize the available space.

Figure 10 Cable Management

STEP 7: Affix the Battery Temperature Sensor
Uncoil and affix the battery temperature sensor in the center of the middle battery string.
N
: The purpose of battery temperature sensor is to monitor the ambient temperature of the batteries over
OTE
long periods of time and adjust the rectifier output (float) voltage accordingly.
N
: Refer to the specifications supplied by the battery vendor for battery operational temperature
OTE
requirements.
STEP 8: Affix the Ambient Temperature Sensor
Uncoil and affix the ambient temperature sensor in a position that will give an indication of average
cabinet/room temperature.
N
: refer to the EM4x energy manager, RM3048HE Rectifier
OTE
STEP 9: Terminate External I/O Connections
Terminate external I/O connections if any to the Energy manager. Refer to the EM4X Relay output and digital
input sections for mappings in the EM4x Manual. The Monitor layout is as shown in
N
: The inputs are normally activated by connecting system positive (usually system common) to the input.
OTE
N
: Route and secure Alarm Extension Loom away from AC and DC cables
OTE
N
: For full EM4x functionality and operation information, refer to the EM4x Manual.
OTE
NewMar Power System Manual
Model: COMMANDER II AND COMMANDER II+
, place the cables across the cable tiedown and secure
2
, place the cables on either side of the cable tiedown and
2
, feed the
2
Figure
12.
M-CMDRII 063022
Page 14 of 43
Version 1.0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Commander ii

Table of Contents