Mobile Data Power Model: MDP-25 Topic Section Features..............Operational Features Summary......Back-up Battery Power Internal Charger Voltage Spike Protection RF Noise Filtering Warning of Imminent Loss of Power Low Voltage Status Indicators Status Indicators Low Power Consumption Mode Materials Provided..........
Features: • Protects mobile computers against system crash preventing lengthy reboot sequences and loss of data due to: • Voltage dip during engine cranking. • Voltage drop and decay due to loading high power accessories and aging batteries. • Provides supplemental voltage in mili-seconds to mobile computers when low vehicle battery is sensed, ensuring no interruption in power.
Using the table below, select the proper wire size for your installation and attach to terminal block. Four rings lugs for 8 AWG wire size are included with the MDP-25. Replace terminal block cover to prevent accidental shorting of the terminals.
Output Signals: The MDP is programmed to provide early warning signals to mobile data computers designed for this input (such as Motorola® MW 800 Series workstations.) Interface signals for this output is located on the D-sub connector per the following pin out (please contact factory for mating connector with pigtails): Signal Key: Ignition OUT 1) Ignition OUT - to be connected to MDC interface with signal which initiates...
MDP input current draw when the internal battery is full charged.) If fuses blow repeatedly, this usually indicates a shorted component. Contact NEWMAR for further trouble shooting advice. Always verify that the replaced fuses are of the correct rating. Use standard ATC fuses. Do no use slow- blow fuses.
FACTORY CONTACT INFORMATION If a problem with the MDP-25 persists after you have applied the above-outlined solutions, or if you have any questions about the installation and proper operation of the MDP-25, please contact NEWMAR’s Technical Services Manager: Phone: 714-751-0488 - From the hours of 7:00 A.M. to 4:30 P.M. weekdays, P.S.T.