NewMar C2R-2000 Installation & Operation Manual
NewMar C2R-2000 Installation & Operation Manual

NewMar C2R-2000 Installation & Operation Manual

24 vdc, 1000 watt/ 48 vdc, 2000 watt rectifier

Advertisement

Quick Links

Centurion II Power System
24 VDC, 1000 Watt/
48 VDC, 2000 Watt Rectifier
Installation / Operation Manual
Model:
C2R-2000
Newmar
2911 W. Garry Ave.
Santa Ana, CA 92704
Tel: (714) 751-0488
Fax: (714) 957-1621
M-C2R-2000
Oct 2010
Powering the Network
Newport Beach, CA USA
www.newmartelecom.com • 800-854-3906

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the C2R-2000 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for NewMar C2R-2000

  • Page 1 Centurion II Power System 24 VDC, 1000 Watt/ 48 VDC, 2000 Watt Rectifier Installation / Operation Manual Model: C2R-2000 Newmar 2911 W. Garry Ave. Santa Ana, CA 92704 Tel: (714) 751-0488 Fax: (714) 957-1621 M-C2R-2000 Oct 2010 Powering the Network Newport Beach, CA USA www.newmartelecom.com •...
  • Page 2: Table Of Contents

      Warnings ......................... 10     Troubleshooting ....................... 10     Fuses ..........................10     Ventilation Details ........................... 11     Warranty ............................12 Newmar • PO Box 1306, Newport Beach, CA 92663 • Phone: 714-751-0488 • E-mail: techservice@newmarpower.com...
  • Page 3: Principles Of Operation

    1 Principles of Operation Introduction The C2R-2000 is a telecommunications grade rectifier with the following features: Hot pluggable Forced Air Cooled Thermally Protected Power Factor Corrected Wide input AC Voltage Constant Power Output Limit Input/Output Voltage and Current Protected Active Load Sharing...
  • Page 4: Power And Current Limit

    1.11 Serial Alarm and Control Interface The rectifier, when installed in a Newmar C2RS rectifier shelf, is controlled via the serial interface by the system monitor. The system monitor can set up control parameters and receive alarm information via this interface.
  • Page 5: Voltage Control

    This pin must be connected to negative bus volts and the rectifier will not start until this pin engages. If a rectifier will not start, ensure the rectifier is fully engaged in the Goldfish connector in the rectifier shelf. Newmar • PO Box 1306, Newport Beach, CA 92663 • Phone: 714-751-0488 • E-mail: techservice@newmarpower.com...
  • Page 6: Interface - Rear Connector

    AC live (phase) conductor Pin 19 AC neutral conductor Note: Unassigned pins should not be connected to anything and should be left isolated and voltage free. Newmar • PO Box 1306, Newport Beach, CA 92663 • Phone: 714-751-0488 • E-mail: techservice@newmarpower.com...
  • Page 7: Installation

    The rectifier contains components at High Temperatures that may burn if touched Rectifier Shelf The C2R-2000 rectifier is designed to be used with the Newmar C2RS rectifier shelf or approved alternative. This shelf will accommodate up to 4 C2R-2000 modules giving a total output capacity of 4.0kW.
  • Page 8: Rectifier Addressing

    3) Once the rectifier is installed into the rectifier shelf, the AC power can be turned on. After the initial start up period the rectifier will be set to the desired system parameters by the monitor module via the serial communications. Newmar • PO Box 1306, Newport Beach, CA 92663 • Phone: 714-751-0488 • E-mail: techservice@newmarpower.com...
  • Page 9: Specifications

    Adjustable to 50 – 100% of maximum rated current Over Temperature Automatic current turndown, backup shutdown protection Polarity Reversal Output Fuse with Crowbar diode Over Voltage Adjustable limit Newmar • PO Box 1306, Newport Beach, CA 92663 • Phone: 714-751-0488 • E-mail: techservice@newmarpower.com...
  • Page 10: Environmental

    EN 61000-3-2 AC Flicker and Fluctuation EN 61000-3-3 Other CE & RoHS compliant Due to ongoing product development specifications are subject to change without prior notice. Newmar • PO Box 1306, Newport Beach, CA 92663 • Phone: 714-751-0488 • E-mail: techservice@newmarpower.com...
  • Page 11: Servicing

    FH183 FST 250mA 250V EFT/MET PCB Fuse FH100 15A 250V ceramic slow blow wire end Fuse FH101 15A 250V ceramic slow blow wire end Fuse Newmar • PO Box 1306, Newport Beach, CA 92663 • Phone: 714-751-0488 • E-mail: techservice@newmarpower.com...
  • Page 12: Ventilation Details

    5 Ventilation Details Newmar • PO Box 1306, Newport Beach, CA 92663 • Phone: 714-751-0488 • E-mail: techservice@newmarpower.com...
  • Page 13: Warranty

    In no event shall Newmar be responsible for indirect or consequential damages or lost profits even if Newmar Ltd has been advised of the possibility of such damages. Newmar sole obligation to you shall be the repair or replacement of a non-conforming product.