HBM Z4A Mounting Instructions page 18

Force transducer with s.g measurement system
Hide thumbs Also See for Z4A:
Table of Contents

Advertisement

18
SUNSTAR传感与控制 http://www.sensor-ic.com/ TEL:0755-83376549 FAX:0755-83376182 E-MAIL:szss20@163.com
If the transducer is connected according to the following connection diagram
then when the transducer has compressive loading the output voltage at the
measuring amplifier is positive.
Six-wire connection
Fig. 6.1: Z4A, Z4A-G pin assignment
SUNSTAR自动化 http://www.sensor-ic.com/ TEL: 0755-83376489 FAX:0755-83376182 E-MAIL:szss20@163.com
WH (white)
Measurement signal (+) U
BK (black)
Excitation voltage (–) U
RD (red)
Measurement signal (–) U
BU (blue)
Excitation voltage (+) U
GN (green)
Sensor circuit (+)
GY (grey)
Sensor circuit (–)
YE (yellow)
Cable shielding, connected to housing
Z4A
A
B
A
B
HBM 20.11.00